ENGINE OIL LEVEL CHECK

Avoid skin contact with engine oil. Wear protective
clothing and equipment. Wash all exposed skin with
soap and water.
ALWAYS use the specified engine oil. Failure to use the
specified engine oil can cause accelerated wear and/or
shorten the life of the engine.
When using the generator under dirty, dusty conditions or
in extremely hot weather, change the oil more frequently.
Ambient air temperature will affect engine oil performance.
Change the type of engine oil used based on weather
conditions.
Check the engine oil level before each use or every 8
hours of operation.
1. Place the generator on a level surface and allow the
engine to cool for several minutes.
2. With a damp rag, clean around the oil dipstick.
3. Remove the oil dipstick and wipe the dipstick clean.
NOTICE
MAINTENANCE
4. Insert the dipstick into the oil filler neck without screwing
it in. Remove the dipstick and verify that the oil level
is within safe operating range between the low (L) and
high (H) marks on the dipstick.
5. If low, add recommended engine oil incrementally and
recheck until the level is between the L and H marks on
the dipstick. DO NOT overfill. If over the H mark on the
dipstick, drain the oil to reduce the oil level to the full
mark.
6. Replace the oil dipstick and hand-tighten.

ENGINE OIL CHANGE

When using the generator under dirty, dusty conditions or
in extremely hot weather, change the oil more frequently.
Change the oil while the engine is still warm from operation.
1. Place the generator on a level surface and allow the
engine to cool for several minutes.
2. With a damp rag, clean around the oil dipstick. Remove
the dipstick and wipe clean.
3. Place an oil pan (or suitable container) under the oil
drain bolt.
4. Using a 10mm wrench, remove the oil drain bolt and
allow the oil the to drain.
5. Install the oil drain bolt and tighten securely.
Note: A new oil drain plug crush washer is recommended
at each oil change.
6. Slowly pour oil into the oil filler neck until oil the level
is between the L and H marks on the dipstick. Stop
frequently to check the oil level. DO NOT overfill.
Maximum oil capacity: 0.74 Quart (0.7 Liter)
7. Install the oil dipstick and hand-tighten.
DO NOT pollute. Follow the guidelines of the EPA or other
governmental agencies for proper disposal of hazardous
materials. Consult local authorities or reclamation facility.