Airfusion Radar Installation Instructions
Always check the "Trouble Shooting Checklist" included in this booklet before calling for service. Unnecessary calls are
inconvenient for all and can attract a service charge.
For your safety, ensure the ceiling fan is OFF before carrying out any troubleshooting.
TROUBLE
1. Fan will not start.
(Warning: The ceiling
fan must be switched
OFF and the assistance
of a licensed electrician
may be required.)
2. Fan wobbles.
(Refer to the Wobble
section in this manual
for further information.)
3. Fan sounds noisy.
4. Mechanical noise.
AIRFUSION RADAR
SERIES DC FAN models
RADAR FAN
12 | P a g e

TROUBLE-SHOOTING CHECKLIST

PROBABLE CAUSES
A. Fuse or circuit breaker blown.
B. Loose power connections to the
fan.
(Normally
occurs
installation.)
C. No response from the remote
transmitter.
D. Switch the fan ON via the mains
switch.
A. Fan blades are not horizontal to
the ceiling.
B. Blade screws are loose.
C. Blade/s are out of shape.
A. Top canopy is touching the
ceiling.
B. Loose fan blade screws.
C. Ceiling fan not secured against
the ceiling.
D. Incorrect speed controller.
A. Allow at least for 8 hours settling-
in period.

TECHNICAL INFORMATION

Rated Voltage
220-240VAC
SUGGESTED REMEDY
Check main and branch circuit fuses or
breakers.
Check power connection to the fan. This must be
during
performed be a licensed electrician.
- Battery is low. Replace batteries.
- Check if correct remote transmitter is paired with
the receiver.
Check if there is power to the fan.
Refer to "wobble" section in this manual.
The blade may require adjustment at the
-
blade mounting screws.
The blade is out of shape, thus causing
-
wobbling. A new blade set will be required to
be replaced. Contact retailer for further
details.
Make sure all screws are securely fastened.
Remove the blades and lay on a flat surface to check
if they are out of shape. Contact retailer for further
details.
Lower canopy from ceiling to ensure a minimum
3mm clearance.
Re-tighten all screws on the fan blades but never
over-tighten.
Re-tighten all screws in the hanging bracket or plate.
Change the controller to the one supplied.
(Must be performed by a licensed electrician.)
Rated power (motor)
35W
circuit
Battery for remote
1 x 12V 23AE