cecotec ENERGYSILENCE 12000 AIR CLIMA CONNECTED Manual De Instrucciones página 49

Ocultar thumbs Ver también para ENERGYSILENCE 12000 AIR CLIMA CONNECTED:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
ENGLISH
Problem 2
Strange odour
Cause
Dirty air filter.
Problem 3
Noise of running water
Cause
Back flow of liquid in the refrigerant circulation.
Problem 3
A fine mist comes from the air outlet
This occurs when the air in the room becomes very cold, as with the cooling or dehumidifying
mode.
Problem 4
A strange noise can be heard
Cause
This noise is made by the expansion or contraction of the front panel due to variations in
temperature and does not indicate a problem.
Problem 5
Insufficient airflow, either hot or cold
Causes
Unsuitable temperature setting.
Obstructed air conditioner intakes and outlets.
Dirty air filter.
Fan speed set at minimum.
Other sources of heat in the room.
No refrigerant.
Problem 6
The appliance does not respond to commands
Causes
Remote control is not close enough to indoor unit.
The batteries of remote control need to be replaced.
Obstacles between remote control and signal receiver in indoor unit.
Problem 7
The display is off
Causes
Inactive light function
94
ENERGYSILENCE 12000 AIR CLIMA CONNECTED
Power failure.
Note:
Switch off the air conditioner immediately and cut off the power supply in the event of:
Strange noises during operation.
Faulty electronic control board.
Faulty fuses or switches.
Spraying water or objects inside the appliance.
Overheated cables or plugs.
Very strong smells coming from the appliance.
Possible error signals
E1: Indoor temperature sensor fault.
E2: Indoor pipe temperature sensor fault
E3: Outdoor pipe temperature sensor fault
E4: Refrigerant system leakage or fault
E6: Malfunction of indoor fan motor
E7: Outdoor air temperature sensor fault
E8: Outdoor discharge temperature sensor fault
E9: Outdoor IPM module fault
EA: Outdoor current detect fault
EE: Outdoor PCB EEPROM fault
EF: Outdoor fan motor fault
EH: Outdoor suction temperature sensor fault
Maintenance instructions
1. Check the information in this manual to find out the dimensions of space needed for proper
installation of the device, including the minimum distances allowed compared to adjacent
structures.
2. Appliance shall be installed, operated and stored in a room with a floor area larger than 4 m
3. The installation of pipe-work shall be kept to a minimum.
4. The pipe-work shall be protected from physical damage, and shall not be installed in an
unventilated space if the space is smaller than 4 m
5. The compliance with national gas regulations shall be observed.
6. The mechanical connections shall be accessible for maintenance purposes.
7. Follow the instructions given in this manual for handling, installing, cleaning, maintaining
and disposing of the refrigerant.
8. Make sure ventilation openings are clear of obstruction.
9. Servicing shall be performed only as recommended by the Technical Support Service of
Cecotec.
10. The appliance shall be stored so as to prevent mechanical damage from occurring.
ENGLISH
.
2
ENERGYSILENCE 12000 AIR CLIMA CONNECTED
.
2
95

Hide quick links:

Tabla de contenido
loading

Tabla de contenido