5. Piping
6. Gasket
7.
Indoor
8. Outdoor
Wind insulating covering around the joints of the indoor unit and fix it with insulating tape.
Fix the exceeding part of the signal cable to the piping or to the outdoor unit.
Fix the piping to the wall (after having coated it with insulating tape) using clamps or any other
fixing element.
Seal the hole in the wall through which the piping is passed so that no air or water can fill.
Indoor unit test
Do the On/Off and fan operate normally?
Does the mode operate normally?
Do the set point and timer operate properly?
Do the light indicators light normally?
Does the air flow direction flap operate normally?
Is condensed water drained regularly?
Outdoor unit test
Is there any abnormal noise or vibration during operation?
Could the noise, the air flow or the condensed water drainage disturb the neighbours?
Is there any coolant leakage?
Note: The electronic controller allows the compressor to start only three minutes after voltage
has reached the system.
Information for the installer
Length of pipe with standard charge: 5 m
Maximum distance between indoor and outdoor unit: 25 m
Additional refrigerant charge: 15 g/m
Max. diff. in level between indoor and outdoor unit: 10 m
Type of refrigerant (1): R290
(1) Refer to the data rating label stuck onto the outdoor unit.
Pipe
Tightening
Corresponding
torque [N x m]
stress
(using a 20-cm
wrench)
1/4"
15-20
Wrist strength
(Ø6 mm)
78
ENERGYSILENCE 12000 AIR CLIMA CONNECTED
Tightening
torque [N x m]
Service port nut
7-9
3/8"
31-35
Arm strength
(Ø9.52 mm)
1/2"
35-45
Arm strength
(Ø12 mm)
5/8"
75-80
Arm strength
(Ø15.88 mm)
Wiring diagram
Fig. 26.
1.
Front panel
2. Wiring diagram
On indoor unit, the wiring diagram is pasted under the front panel;
On outdoor unit, the wiring diagram is pasted on the backside of the outdoor handle cover.
Fig. 27.
1.
Outdoor handle cover
2. Wiring diagram
Type of connection
Fig. 28.
1.
Outdoor
2. Indoor
3. Power supply
5. OPERATION
Remote control display
Fig. 29.
1.
Auto mode
2. Cooling mode
3. Dehumidifier mode
4. Fan mode
5. LED display
6. Heating mode
7.
Timer
8. Indoor display on
9. Sleep function
10. Eco function
11. Self-clean function