MENU 12 – ACTIVE FUNCTIONS - OFF - the stove remains on the configured SET.
TURBO function: like the QUICK function with the difference that the heater does not modulate P1 power with set
ambient or set water satisfied but modulates only in the flue gas safety condition.
QUICK function: pressing this button forces the machine power onto P5, saving the previous set power.
Ventilation, too, if present, is forced onto AUTOMATIC (so maximum ventilation); saving the previous ventilation
value. When pressed with the comfort function activated, it restores power and ventilation to the previous saved
value. With set ambient or set water satisfied the heater modulates P1 power together with ventilation.
COMFORT function: pressing this button forces power and ventilation onto P1. Deactivating this function will take
the power and ventilation to the value prior to activation.
This function observes and performs STANDBY.
4.2.5

Replacing the battery

The remote control is powered by three batteries located in the back of the device. For insertion and possible
replacement, proceed as follows:
- Open the cover on the back of the remote control;
- Replace the AAA 1.5 V batteries, respecting the
polarity;
- Close the remote control
- Keep the remote control away from direct heat sources and water.
- The battery of the remote control must be replaced and disposed of in a safe way,
respecting the local regulations;
4.3
Use via control panel
To access the panel, remove the protection profile in the bottom of the stove .
Press button P3 on the control panel for a few seconds to turn the stove on and off. Use buttons P1 and P2 to set
the maximum power, indicated by the LED of button P2. Then the medium power equal to power 3, indicated by
lighting up of the LED of buttons P1 and P2, and lastly the minimum power, indicated by the LED of button P1.
It is not possible to set the temperature, the intermediate operating powers or access the various menus with the
emergency panel.
4.4
Optional probe and external thermostat
The standard unit controls the room temperature by means of a probe that adjusts the power according to the set
temperature. The probe is positioned in the remote control and measures the temperature in the place where the
remote control is located. The user can choose to use an external thermostat, connected directly to the
motherboard, whose sensor can be located in the most suitable place.
In case of an external thermostat, it is necessary to use a 'normally open' type.
Contact an authorized technician and follow the following instructions:
-
turn the unit off at the main switch and disconnect the power cable;
-
remove the stove from the compartment and access the motherboard;
-
referring to the wiring diagram, connect the two thermostat wires to the respective terminals TERM of the board;
-
refit everything, then set RADIO PROBE in menu 10;
-
-
Then set as follows:

in case of external thermostat: Set a temperature of 7°C on the remote control and adjust the external
thermostat setting as desired;

in case of external chronothermostat: Set a temperature of 7°C on the remote control and adjust the
external chronothermostat setting as desired.
It is compulsory to disable the chrono function in menu 03 and set the STANDBY function to ON. When the
set temperature is reached, the stove will shut down and not go to modulation.
In any case, it is advisable to use the stove
chronothermostat setting function.This will avoid creating conflicts between the stove programming and
that of the chronothermostat
Cover
time programming function and only the external
44