Dometic CC09 Instrucciones De Uso página 12

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Installing the hob
 Keep the hose connection between the gas appliance and the liquid gas
supply system as short as possible, and no longer than 750 mm.
 The entire hose connection must be accessible for inspection purposes.
 During operation, air vents must have a cross-section of at least 50 cm
in the installation space. These vents can be closed, but must be kept
open when the device is in use.
➤ Connect the hob to the gas supply.
➤ Attach a sign above the hob with the following text:
"WARNING!
When cooking, provide additional ventilation e.g. by opening windows
near the grill, hob or oven.
This equipment must not be used for heating the room."
➤ Make sure that the hose line:
– is not crushed or kinked
– is a safe distance from the burner
➤ Open the valve on the gas cylinder.
WARNING! Beware of injury
!
Never check for leaks with a naked flame or near sources of igni-
tion.
➤ Check all connections with leak spray.
There are no leaks if no bubbles form.
12
All manuals and user guides at all-guides.com
CC09, CCK09, CC11
2
EN
Tabla de contenido
loading

Este manual también es adecuado para:

Cc11Cck099103303387910330338691033033909103303391

Tabla de contenido