5.To disconnect the inverter, reverse the above steps.
NOTE: The internal speaker may make a brief "beep"
when the inverter is being connected to or disconnected
from the 12-volt power source.
ATTENTION: Failure to make the correct connections
will result in blown fuses and permanent damage to the
inverter.
7.
USING THE GfCI OUTLET (MODEL PI-1500
ONLY)
The PI-1500 inverter includes two "GFCI" (Ground Fault
Circuit Interrupter) outlets located on the right side of the
inverter. The purpose of a GFCI outlet is to quickly stop
the flow of electricity in the event a ground fault occurs
on the device plugged into the inverter's GFCI outlet.
Use only 3-prong grounded plug when using the GFCI
outlet.
The GFCI outlets provide auxiliary power to 120V AC
devices that require less than 15-amps.
The GFCI outlets provide auxiliary power to 120V AC de-
vices that require less than 15 amp. If using both GFCI
outlets at the same time, the amperage cannot exceed a
total of 15 amps for both devices combined.
The GFCI (Ground Fault Circuit Interrupter) must be
tested before each use. To test:
1. Connect the inverter (see "CONNECTING INVERT-
ER CABLES" section).
2. Turn the inverter on.
3. Push the "Reset" button located on the GFCI recep-
tacle, first to assure normal GFCI operation.