13.
TROUbLESHOOTING
PRObLEM
Red LED is on, audible
alarm is on, and/or in-
verter does not function.
14.
SPECIfICATIONS
Model: PI-1000
Maximum Continuous Power
Surge Capability (Peak Power)
No Load Current Draw
Wave Form
Input Voltage Range
Output Voltage Range
Low Battery Alarm
Low Battery Shutdown
High Battery Shutdown
Optimum Efficiency
AC Outlet
Dimensions
Weight
All manuals and user guides at all-guides.com
REASON
Poor contact at terminals.
Fuse Blown.
Inverter shutdown.
Inverter may not be work-
ing properly.
Audible, 10.3V – 10.6V DC
• 17 •
Check the connections at
power supply.
See "IF THE INVERTER
FUSE BLOWS" section.
See "LED INDICATOR
AND SHUTDOWN PRO-
TECTION" section.
See Warranty and call
Customer Service 1-800-
621-5485 (Hours: 7:00
am – 5:00 pm CST).
1000 Watts
2000 Watts
Modified Sine Wave
10.5V – 15.5V DC
120V ± 5% AC
10.5V ± .5V DC
15.0V – 16.0V DC
Two, 120V AC 3-Prong
10.5" L x 9" W x 3.75" H
approximately 7.25 lbs.
SOLUTION
<0.25A
>80%