Error Description And Remedy; Maintenance And Cleaning; Special Safety Advice - G-U BKS SECURY 21 EK Serie Instrucciones De Montaje

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation instructions
SECURY 21 EK | 21 EK EVP | 21 S | 21 S EVP
Multi-point locks electrically couplable or with monitoring contacts
SECURY 2116 S / 2116 S EVP / 2119 S:
Latchbolt (locked or not locked)
Cylinder cam / position of the key (initial position or actuated)
4.3
Description
SECURY 2170 / 2170 EVP / 2171:
Operating current (fail-secure)
version:
Outside lever handle cannot be
coupled in electrically
Quiescent current (fail-safe) version:
Outside lever handle cannot be
decoupled electrically
SECURY 2178:
Operating current (fail-secure)
version:
Outside and inside lever handles
cannot be coupled in electrically
Quiescent current (fail-safe) version:
Outside and inside lever handles
cannot be decoupled electrically
SECURY 2116 S / 2116 S EVP / 2119 S:
The monitoring contact
"latchbolt" reports no
signal with the door closed
If you have any other questions, please contact our after-sales service.
5.
5.1
The multi-point locks SECURY 21 EK / S / EVP must only be operated with
power supply units meeting at least the specifi ed requirements (see chapter
"2.5 Technical data").
There is no warranty if this is not observed.
DE
52
All manuals and user guides at all-guides.com

Error description and remedy

Maintenance and cleaning

Special safety advice

EN
FR
ES
Solution
Power supply is lacking.
Make sure that the power supply is connected correctly.
Cable(s) connected incorrectly or not at all.
Make sure that all cables are correctly connected.
The power supply unit does not provide current.
Make sure that the power supply unit functions correctly.
Replace the micro-fuse if necessary.
Power supply is lacking.
Make sure that the power supply is connected correctly.
Cable(s) connected incorrectly or not at all.
Make sure that all cables are correctly connected.
The power supply unit does not provide current.
Make sure that the power supply unit functions correctly.
Replace the micro-fuse if necessary.
The latchbolt does not project completely.
Check whether the cut-out in the latch striker is deep enough
(min. 20 mm) so that the latchbolt can project completely.