Operating instructions
Fingerprint scanner and code keypad
3 Functions in conjunction with the programming device
Each time a button is pressed, the green LED lights up to confirm this. If the green LED does not light
up, repeat the input.
3.1 Abbreviations and key assignments of programming
device:
MF
=
Master Finger
E
=
Enroll (record finger)
D
=
Delete (delete finger)
DA
=
Delete All (delete all, incl. master finger)
H
=
Security (High), M = Security (Medium), L = Security (Low)
RT
=
Relay switching Time
B
=
Block (block IDs)
UB
=
Unblock (unblock IDs)
Function
Teach-in master
finger
Teach in user finger
Identification
Delete a user finger
Delete all fingers
(reset)
Setting the security
level
Set the security
level
Set the security
level
Set the relay
switching time
(only with on-
wall/in-wall
version)
Block IDs
Unblocking IDs
Check ID
Unblock the
terminal
Operating instructions, edition 3 dated 03/01/2013
Copyright © G-U GmbH, 2012. All rights reserved.
Description
Defining administration
finger
Scan user finger,
connected with an ID
Individual deletion via
the ID
Reset to initial state
Security (High,
corresponds to 5-digit
PIN code)
Security (Medium,
corresponds to 4-digit
PIN code)
Security (Low,
corresponds to 3-digit
PIN code)
Relay switching time: 1 s
to 60 s
Blocking users
temporarily (e.g. guests)
Unblocking users
Checks whether an ID
has already been
assigned
Exit blocking mode
Procedure
Delivery condition teach in master finger three
times
MF E ID OK
Scan user finger MF
Scan user finger
MF D ID OK MF
MF DA MF
MF H
OK
MF M
OK
MF L
OK
RT
Digit(s)
OK
MF B ID
OK
MF
UB
ID
OK
OK
ID
OK
Drag a taught-in finger (master or user finger)
across the sensor twice in direct succession
Page 37