Installation instructions
SECURY 21 EK | 21 S
Multi-point locks electrically couplable or with monitoring contacts
4.3
Description
SECURY 2170 / 2171:
Operating current (fail-secure)
version:
Outside lever handle cannot be
coupled in electrically
Quiescent current (fail-safe)
version:
Outside lever handle cannot be
decoupled electrically
SECURY 2178:
Operating current (fail-secure)
version:
Outside and inside lever handles
cannot be coupled in electrically
Quiescent current (fail-safe)
version:
Outside and inside lever handles
cannot be decoupled electrically
SECURY 2116 S / 2119 S:
The monitoring contact
"latchbolt" reports no
signal with the door closed
If you have any other questions, please contact our after-sales service.
DE
56

Error description and remedy

EN
FR
ES
Solution
Power supply is lacking.
Make sure that the power supply is connected correctly.
Cable(s) connected incorrectly or not at all.
Make sure that all cables are correctly connected.
The power supply unit does not provide current.
Make sure that the power supply unit functions correctly.
Replace the micro-fuse if necessary.
Power supply is lacking.
Make sure that the power supply is connected correctly.
Cable(s) connected incorrectly or not at all.
Make sure that all cables are correctly connected.
The power supply unit does not provide current.
Make sure that the power supply unit functions correctly.
Replace the micro-fuse if necessary.
The latchbolt does not extend completely.
Check whether the cut-out in the latch striker is deep
enough (min. 20 mm) so that the latchbolt can extend
completely.