How To Stop; Before Starting - DeWalt DXCMLA4708065 Manual De Instrucciones

Compresores eléctricos de aire, de una sola etapa y accionamiento por correa
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Use pipe that is the same size as the air tank outlet. Piping that
is too small will restrict the flow of air.
If piping is over 100' (30.5 m) long, use the next larger size.
Bury underground lines below the frost line and avoid pockets
where condensation can gather and freeze. Apply pressure
before underground lines are covered to make sure all pipe
joints are free of leaks.
A flexible coupling is recommended to be installed between
the globe valve/air discharge outlet and main air distribution
line to allow for vibration.
A separate regulator is recommended to control the air
pressure. Air pressure from the tank is usually too high for
individual air driven tools.
DO NOT install lubricators between the tank and any spray
equipment, air tool or accessory requiring oil-free filtered air.
Drain all traps, filters and dirt legs daily.
FEEDER LINES SLOPE
AIR FLOW
WITH AIR FLOW
MAIN DISTRIBUTION AIR LINES
Slope pipe in di rection of air o w.
Water condensate ows along
bottom of pipe to drain legs,
preventing it f rom entering feeder
lines.
.01 MICRON
5 MICRON
FI LTER
FI LTER
SPR AY
GUN
REGUL ATOR
BALL
FI LTER
FOR BEST PERFORMANCE
FI LTER /
the distance between the
MOISTURE
comp ressor and the
TRAP
moistu re trap should be as
long as possible
DRAIN
TYPICAL
VALVE
COMPRESSED AIR
DISTRIBUTION
SYSTEM
RISK OF BURSTING. ALWAYS USE
METAL PIPING AND FITTINGS.
How to Use Your Unit (Fig 3)

How to Stop:

Set the Auto/Off switch to "Off".

Before Starting

WARNING: Do not operate this unit until you read this instruction
14
AIR FLOW
DRAIN
AIR USAGE
LEGS
LINES
DRAIN
VALVES
FI LTER /
MOISTURE
TRAP
DIR T
LEGS
REGUL ATOR
LUBRIC ATOR
DRAIN
VALVES
AIR
TOOL
FLEXIBLE
COUPLING
GLOBE VALVE /
AIR DISCHARGE
VALVE
AIR
COMPRESSOR
DRAIN
VALVE
Tabla de contenido
loading

Tabla de contenido