7.
Program structure
i
After the SBM 55 NW is switched on, the software
version appears in the control/display panel for
several seconds. After this, both displays show the
value 0.
7.1
Control/display panel
7.1.1
Overview of LEDs
Fig. 9:
LEDs on control/display panel
Item Description
1
Displays the active (selected) balancing program and
balancing positions (see sections 8.2).
2
Indication of external weight balancing point; it lights-up
green when the balancing position is reached.
3
Displays the Split program and Match program, lights up
when programs are active (see sections 8.6.3 and 9).
4
Displays the unit of measurement for the rim width and
rim diameter,
lit = mm,
not lit = inch.
5
Displays the balancing program,
lights up when Pax program is selected.
6
Displays the Match program, lights up when Match
program is active.
7
Displays the direction of rotation to reach the balancing
position,
top = turn clockwise,
bottom = turn anti-clockwise.
8
Indication of internal weight balancing point; it lights-up
green when the balancing position is reached.
9
Internal weight display.
10
External weight display.
Sicam srl società unipersonale
651076-34_Im
Program structure | SBM 55 NW | 41
7.1.2
Control buttons
1b
5 4
Fig. 10:
Buttons on the control/display panel
Item
Button
Description
1a
<->
Changes the rim diameter
1b
'or
Changes the rim width values.
1c
<+>
Changes the rim distance,
2
<SPLIT>
Opens and closes the program for splitting
the balancing weights.
3
<mm/
If LED is on it indicates the measurement
inch>
unit is in mm; vice-versa, it is in inch.
4
<MODE>
Selects the balancing program
5
<MENU>
Performs basic settings.
6
<START>
Starts measurement.
7
<STOP>
Stops measurement, locks the SBM 55 NW in
case of emergency.
Tab. 1:
Function of control buttons
1c
7
6
|
1 695 656 076
2012-03-28
en
1a
2
3