LIFT CORPORATION Sht. 18 of 58 DSG#
Pump cover must be correctly secured to prevent it from becoming a
hazard. To secure pump cover, the long side of the holder fl ats must butt
against pump cover as shown in the illustration.
9. Bolt on the pump cover as shown in
FIGS. 18-1 and 18-2. For GPT pump
covers, hand tighten the threaded
cover knobs (FIG. 18-1). For GPTLR,
MXT, and TE-33 pump covers, torque
the cover bolts from 10-14 lb-ft (FIG.
18-2).
© MAXON Lift Corp. 2020
CAUTION
CAP SCREWS
(2 PLACES)
HOLDER FLATS
(2 PLACES)
M-19-05
BOLTING ON PUMP COVER (GPT)
FIG. 18-1
FLAT WASHERS
(2 PLACES)
PUMP
COVER
BOLTING ON PUMP COVER
(GPTLR, MXT & TE-33)
FIG. 18-2
Rev. A Date: 10/14/20
HEX NUTS
(2 PLACES)
POWER UNIT
(REF)