M-19-05
LIFT CORPORATION Sht. 16 of 58 DSG#
Rev. A Date: 10/14/20
5. Disconnect fuse holder from terminal 1 on
the ECU module and the male bullet on the
GREEN wire from control switch (FIG. 16-1).
Discard fuse holder. Then, reinstall hex nut on
terminal 1 of the ECU module. Torque hex nut
to 15 lb-in maximum.
FEMALE BULLET
MALE BULLET
GREEN
FUSE HOLDER
MAX ECU
MODULE
REMOVING FUSE HOLDER FROM TUK-A-WAY
LIFTGATES EQUIPPED WITH MAX ECU MODULE
FIG. 16-1
© MAXON Lift Corp. 2020