T ROUBL ESH OOT ING

For more severe problems, see Complete User manual on www.bluewatergroup.com
1
2
Symptom
1
The ON light is not on.
2 The FILTER light flashes,
and the yellow light on
the faucet flashes.
3 The FILTER light is on,
and the yellow light on
the faucet is on.
4 The SERVICE light
flashes, and the green
light on the faucet is
on. The water purifier
produces water.
5
The SERVICE light is on,
and the yellow light on
the faucet is on.
6 The SERVICE light
flashes quickly and
the yellow light on the
faucet is on.
7
The water purifier
makes noise because
the water pressure is not
sufficient.
Or
The FILTER light flashes
quickly and the yellow
light on the faucet is on.
8 The FILTER light and
the SERVICE light flash
quickly and the yellow
light on the faucet is on.
The water purifier does
not start.
Spirit 300: The faucet
light is not on.
3
4
Cause
The water purifier is not
connected to power.
The filter must be replaced.
The water purifier has stopped.
The filter must be replaced.
The water quality has decreased,
but is safe to drink. The water
purifier will stop soon, see 5.
The water purifier has stopped. A
filter replacement has caused air
to come into the system.
The water purifier has stopped.
The clean water quality has
become too low.
The water quality meter does not
function.
The inlet pressure is lower than
1.5 bar during operation.
The grid filter is blocked.
The filter is blocked.
The low pressure restart function
is active.
The overflow protection system
is activated.
The water purifier flushes water.
There is a problem with the
electronic faucet.
The faucet cable is not
connected.
5
6
Solution
Connect the water purifier to
power.
See Complete User manual.
See Complete User manual.
Contact Bluewater to replace the
membrane.
Disconnect the water purifier
from power.
Reconnect it. Let the water
purifier do the automatic flush.
Contact Bluewater to replace the
membrane.
Contact your Bluewater dealer.
Contact your Bluewater dealer.
See Complete User manual
See Complete User manual
See "Low pressure protection" or
Complete User manual
Disconnect the water purifier
from power, and clean the base
plate. If the overflow protection is
activated again, contact your
Bluewater dealer.
Wait for 5 minutes.
Contact your Bluewater dealer
Make sure that the faucet cable
and connector are connected.