5.2
Assembly Recommendation
See point 5.4
5.3
Electrical Connection
WARNING! Hazards resulting from electrical power are to be prevent-
ed.
WARNING! Voltage on the housing may cause electric shock.
05/2013
VG 766.2330.061
VED and EVU specifications and by-laws of the local power supply
company must be followed.
The swimming pool and its protective area must be in accordance
with DIN VDE 0100-702.
A disconnecting device has to be installed to cut off the power sup-
ply (contact opening according to the conditions of the overvoltage
category III).
Set the motor protection overload switch settings. Take the values
on the type plate into consideration.
Protect the electric circuit by means of an earth leakage switch:
residual current I
N
Only use cable types pursuant to the regional regulations.
Check that the min. diameter and length of the cable used is suita-
ble for the current drawn by the motor. See values on the motor ty-
pe plate.
Division 2
Division 2 (1,5m)
Division 1 (2m)
Empty hose for powe cable
Distance equalization
30 mA.
5 Installation
Division 1
Earth
≤45 mm
(Acc. to EN 13451)
Division 1
Division 0
Division 0
EN 49