compressor ON and OFF with compressor OFF, 5 = set with F1, F2 and FF with
compressor ON and also timed with compressor OFF with Fc deactivation delay
upon compressor shut-down and intermittent operation according to times
assigned to Fd and FE)
F4
evap. vent. operation during defrost and dripping (0= OFF, 1= ON, 2= determ.
with F7)
F5
evaporator fan stop after dripping
F6
temperature below which the condenser fan turns off
F7
condenser fan differential (relating to F6)
F8
condenser fan func. during regular operation (0=parallel with compr.; 1=ON);
also refer to F6 and F7
condenser fan func. during defrost and dripping (0=OFF; 1=ON, 2=ON if Tc≥35°C
F9
and OFF if Tc<33°C)
FA
critical temperature for signalling high condensation temperature
Fb
critical temperature for high pressure akarm
Fc
evaporator fan deactivation delay upon compressor shut-down (only if F3 = 5)
Fd
evaporator fan ON time with compressor off (only if F3 = 5)
FE
evaporator fan OFF time with compressor off (only if F3 = 5)
FF
temperature difference between cell and evaporator for fan activation in
continuous mode
P0
Enable device numerical identification for data printing/downloading (0 = no, 1 =
yes)
P1
Sampling time (see also parameter P6)
P2
Selection of temperature probes for which the read value shall e
printed/downloaded
(0 = none, 1=chamber probe, 2 = chamber and evaporator probe, 3 = all)
P3
Payslip heading selection (0 =excluded, 1= Refrigerator, 2=Refrigerated
counter)
P4
Enable device numerical identification for data printing/downloading (0 = no, 1 =
yes)
P5
Selection of language for payslip heading (1 = Italian, 2 = English, 3 = French,
4 = Spanish, 5 = German)
P6
Configuration parameters printing enable (0 = disabled)
L1
Instrument address (date detected in printing phase if P4 = 1)
L2
Serial port management (o = not utilised, 1 = print, 2 = download data on
USB/RTC data logger)
L3
Baud Rate data transmiss. (1=2400, 2=4800, 3=9600, 4=18200)
L4
Transmission control mode (0 = no parity, 1 = odd, 2 = even)
USER PARAMETER CONFIGURATION - PROBE READING
PRINT/DATA DOWNLOADING
COMMUNICATIONS MANAGEMENT
Press the on/sby/enter key over 5 secods (thus avoiding Sby) to gain
access to probe reading and user parameter list.
The display shows the first label "Pd"
Use the up and down keys to scroll probe and parameter reading.
27
-
0
2
min
0
15
°C
-55
+99
°C
1
25
-
0
1
-
0
2
°C
-55
+99
°C
-55
+99
s
0
240
s
0
900
s
0
900
°C
0
+99
-
0
1
-
1
60
-
0
3
-
0
2
-
0
1
-1
5
-
-
1
2
-
0
256
-
0
1
-
1
4
-
0
2