The air condenser should be kept clean to ensure the cabinet's performance and
efficiency, as air should circulate inside the cabinet without barrier.
The condenser should therefore be cleaned every 30 days or as needed.
Dirty condensers result in compressor failure, product loss, and lost sales, which are not
covered by warranty.
Remove the protection panel out in the upper part of the cabinet.
Use a vacuum cleaner, brush or non-metallic brush to carefully clean the
condenser of the cooling unit.
Reposition the protection panel out in the upper part of the cabinet.
WARNING: The cleaning and mantainance of
the refrigerating engine and the compressor area
needs the intervention of a skilled technician,
therefore it cannot be done by other persons.
Clean the external and internal surfaces with water and neutral soap or
detergent; a little vinegar in the water will remove eventual bad smells.
Rinse abundantly with pure water and dry up accurately.
The cleaning and mantainance operations have now come to end.
To guarantee a perfect hygiene and conservation of the refrigerated cabinet it is
recommended to carry out often and/or daily the cleaning operations as indicated
hereunder:
1. Carefully wash the external parts only through the satin finish, wiping with a squeezed
sponge previoulsy soaked in mild detergent.
2. The detergents must not contain chlorine and must not be abrasive.
2.a The kind of detergents recommended are the ones indicated
hereunder:
• Composite action disinfecting detergent;
(containing non-ionic surfactants, benzalkonium chloride,
chelating agents and pH buffer)
• Laboratory, neutral detergent for hand washing;
(containing anionic and non-ionic surfactants)
• Food environments degreasant;
(containing anionic surfactants and EDTA)
DAILY CLEANING
14