Operation
PLC connection to the vehicle
This function is only visible and configurable for the
Customer service user. With the deactivation of the
PLC connection, no further data is transferred via the
cable to the vehicle.
This status is required for example during certain
measurements.
With data transfer, charging that is based on the
charging protocol is enabled by default (high level
communication).
Without data transfer, the charging process is based
on electrical key values (pulse width modulation).
Adding an energy manager
To ensure the energy manager takes over control
of charging, the charger (EEBus device) and energy
manager must first be connected to one another. The
connection is to be established both in the energy
manager's web application and the charger's web
application (or directly on the charger if desired).
Establishing a connection to the charger on the en-
ergy manager
g Connection to the charger is described in the sec-
tion "Adding an EEBus device" in the web application
instructions of the Porsche Home Energy Manager.
Establishing a connection to the energy manager
on the charger
b The charger and energy manager are in the same
network.
1. Navigate to Connections e Energy manager in
the charger's web application.
The energy manager is displayed in the
Available energy managers list.
2. Select energy manager and expand.
30
3. Select Pair devices.
The connection is checked.
4. In the Establish connection dialog box, check the
identity of the energy manager again using the
identification number (SKI) and then select the
option Connect.
The energy manager is successfully con-
nected and the status Energy manager con-
nected is displayed.
The energy manager settings (e.g. charging
current, overload protection and optimized
charging, as well as tariff settings) are ap-
plied to the charger.
Disconnecting the connection to the energy man-
ager:
1. Navigate to Connections e Energy manager in
the charger's web application.
The connected energy manager is displayed
with the status Energy manager connected.
2. Select Disconnect.
The connection between the energy man-
ager and the charger is disconnected.
Linking user accounts
Information
In order to transfer data to your Porsche ID account,
the device must be connected to the Internet.
Information on the charging sessions can also be
called up in your Porsche ID account. To do this,
however, the charger must be linked to a Porsche ID.
1. Select the Link user account button.
The dialog Link user account is opened.
2. Depending on whether an Internet connection is
available, select the following option (see "Inter-
net connection options").
3. On the website for the Porsche ID account, enter
the login data (Porsche ID, password).
Internet connection options
Option
Explanation
b Web application with Internet
To My Por-
sche
connection.
e
You are forwarded directly to
your Porsche ID account.
b Web application without In-
More op-
tions
ternet connection.
e
Using a mobile end device
that has an Internet connec-
tion, either scan in the QR
code displayed or enter the
displayed URL manually in the
browser.
Settings
System
Demo mode
This setting is only visible for the Customer service
user. In demo mode, the functions of the charger can
be displayed easily and a charging session simulated.
The settings made in demo mode are not applied.
b Customer service user is logged in.