Malfunctions
Situation
The charging current is too low (message on display).
The grid voltage is too high (message on display).
The charger is not within the permitted temperature range (message on display).
The circuit breaker in the domestic installation was triggered (message on dis-
play).
A charging interruption is displayed:
e
Power button lights up white.
e
Status LEDs flash blue.
e
The display turns on.
Moving and storage instructions
Do not lift, carry or move the charger by the supply
cable, vehicle cable, power plug or vehicle plug.
Always lift, carry and move the whole device. Do not
damage the control unit, cables or plugs when mov-
ing, e.g. by dragging over the floor or sharp edges.
Proper storage: Store in a cool dry place away from
direct sunlight, not below -22 °F (-30 °C) or above
+122 °F (+50 °C).
36
Recommended action
e
The home network is overloaded. Switch off other high-usage electrical
loads.
e
Have the domestic installation checked by a qualified electrician.
e
Device temperature switch-off: Avoid direct sunlight and let the charger cool
down slowly by itself.
e
Low-temperature switch-off: Let the charger heat up in a warm environment
before using it.
e
Device temperature sensor faulty: Have the charger replaced.
e
Reduce the charging current in the settings on the charger.
e
Acknowledge any error message that appears.
e
Wait until the vehicle resumes charging again automatically.
e
The charging process can be stopped at the vehicle.