Operation
Deactivating and activating ground
monitoring
Electric shock, short cir-
DANGER
cuit, fire, explosion
Using the charger without active ground monitoring
can cause electric shocks, short circuits, fires, explo-
sions or burns.
e
The charger must preferably be operated in
grounded power grids.
e
Only deactivate ground monitoring in non-
grounded power grids.
e
Activate ground monitoring in grounded power
grids.
g Refer to chapter "Activating ground monitor-
ing" on page 26.
Deactivating ground monitoring
b The error message about the interrupted or non-
existent ground wire is shown on the display.
b Ground monitoring has stopped the charging
process or is preventing it from starting.
Power button lights up red.
Status LEDs light up red.
An error message is shown on the display.
1. To deactivate the ground monitoring, acknowl-
edge the error message with Confirm.
2. Press and hold power button
3. Acknowledge the deactivation of ground moni-
toring by pressing Confirm.
Ground monitoring remains deactivated for
subsequent charging sessions as well.
26
Activating ground monitoring
If you are operating the charger in a grounded
power grid, activate ground monitoring.
1. Open Ground monitoring menu (Settings
Ground monitoring).
2. Activate ground monitoring via Activate.
When ground monitoring is active, the menu
item Ground monitoring does not appear in the
Settings
menu.
Logging into the web application
For standard operation of the web application, use
the Home user profile. The Customer service profile
has additional setting options and is intended for use
by your authorized Porsche dealer.
b Access data is to hand.
1. In the User field, select the corresponding user.
2. Enter password (from the letter containing ac-
cess data).
Information
After 25 minutes of inactivity, the user is automati-
cally logged off from the web application.
Opening the web application
Further configuration options and detailed informa-
tion about the previous charging processes can be
for 3 seconds.
displayed using a web application, which is specific to
each charger.
Information
−
Depending on which browser you are using, the
web application will not open immediately; in-
stead information about the browser's security
e
settings will be displayed first.
−
The manner of entering the network key for call-
ing up the web application depends on the end
device's operating system.
Opening the web application via the hotspot
The web application can be called up using an end
device (PC, tablet or smartphone) via a hotspot set
up by the charger.
To set up a hotspot:
e
Refer to chapter "Hotspot" on page 22.
e
To open the web application while a hotspot
is active, enter the following IP address in the
browser's address line: 192.168.0.1
Opening the web application via WiFi
The web application can be called up in the browser
on a device (PC, tablet or smartphone) that is logged
into the same home network as the charger.
–
Enter the current IP address of the charger in the
browser's address line. You will find the current
IP address under Settings
work information.
– or –
Enter the host name of the charger in the brows-
er's address line. You will find the host name in
the letter containing access data.
e Network e Net-