FES-200 W3
3.6 Specific safety instructions
Health risk caused by harmful dust
Before and during operation, please observe the following:
• The fume extraction system contains harmful dust as of the first use.
• The system my only be emptied and maintained by authorized personnel (in Germany see
• The fume extraction system must not be operated without the filter system.
• The fume extraction system must not be operated with open dust collecting drawer.
• During operation and fume extraction, the complete fume extraction system must be kept closed.
• The fume extraction system must only be used for extracting and separating welding fume.
• Freely accessible intake joints and compressed air connections must be protected using a seal plug.
• Do not draw in liquids, aggressive gases, inflammable media or glowing particles (smouldering nests or
similar).
• Do not use or store the fume extraction system outdoors under humid conditions.
• It is not allowed to use the fume extraction system when welding oil-contaminated metals. Risk of fire!
• The 115 V / 60 Hz or 230 V / 50 Hz socket must be protected by a 16 A fuse
• If it is necessary to replace the mains or device connecting cable, only versions indicated by the
manufacturer must be used.
• Make sure that the extraction hose is not damaged by rolling over, crushing, tearing it.
• When using the welding fume filter, the volume flow led back to the work area must not exceed 50 % of
the supply air of the installation area. In case of free room ventilation, the supply air flow corresponds to
one room volume per hour. This corresponds to an air change number of 1/h.
Supply air flow [m³/h] = room volume [m³]
Example: When using an ABICOR BINZEL welding fume filter with a rated volume flow of 200 m³/h,
the same quantity of fresh air must be supplied. With natural ventilation, this is the case if the work area
volume is at least 2000 m³ (e.g.: surface of 58 m² multiplied by room height of 3.5 m).
3.7 Safety instructions for the mains connection
• The mains connecting cable must be checked for damage and wear at regular intervals.
• The fume extraction system may only be operated with an undamaged mains connecting cable.
• Only authorized personnel is allowed to replace the mains connecting cable and the mains plug. (in
Germany see TRBS 1203).
• When replacing the mains plug of the mains connecting cable, the splash guard and the mechanical
strength must still be guaranteed.
• Use a rubberised cable H07RN-F3G1.5 when replacing the mains connecting cable.
• A VDE-certified safety plug must be used for replacing the mains plug of a fume extraction system with
alternating current drive.
• Make sure that the mains connecting cable is not damaged by rolling over, crushing, tearing it.
4 Scope of delivery
• Fume extraction system with mains connection of 115V/230V
• Rubber connector
Tab. 5
Order the equipment parts and wear parts separately. Order data and ID numbers for the equipment parts
and wear parts can be found in the current ABICOR BINZEL spare parts and wear parts lists. The contact
for consulting and ordering can be found on the Internet at www.binzel-abicor.com.
WARNING
TRBS 1203) wearing the respective protective equipment.
Scope of delivery
air change number [1/h]
*
• Extraction hose (l=5.00 m)
• Dust collecting bag (10 pieces)
4 Scope of delivery
EN - 7