Pressing the blue program selection button, the following screen will show the stored programs and their names,
as well as an icon representing those programs that are still void.
Select a void program and introduce the name and bending angles to create a new program. You can also
modify or delete an existing program to introduce the new one.
In the example (left image), the program number (1) and name is
shown on the top. The name can be modified by pressing this button. The red
button deletes the selected program, while the blue one must be selected to
load a new program.
Each of the green buttons with the angle icon is a
memory of the program that you can choose and set or erase by pressing
them and introducing or deleting the desired angle. The sequence must be
correlated (no intermediate memory can be left blank). The orange button
with the angle icon is the calibrating angle, which can be used to fine tune the
angle selection (the correction introduced in this calibration applies to all the
other programmed memories). On the bottom right part of the screen you
can find the counter of bended bars, that will score at the end of every
program sequence performed.
23