POGLAVJE 4
4.3 Zaporedje delovanja
SECTION 4
4.3 Sequence of Operation
PILOT
ARC
4.4 Arc Initiation Settings
Apply Power
PANEL
REMOTE
HIGH
LOW
ACTUAL AMPS
PRESET AMPS
Begin
Cutting
1. Apply power by closing the line (wall) switch.
1.
Vključite napajanje z vklopom stikala na dovodni liniji
(The ESP-400C does not have an on/off
napajanja. (ESP-400C nima ON/OFF stikala). Kontrolna lučka
switch). The main power light will illuminate
glavnega napajanja bo zasvetila in lučka za napake se bo na
and the fault light will flash and then go out.
kratko vklopila.
2.
Izberite način upravljanja Panel/Remote (Kontrolna plošča/
2. Select the Panel/Remote setting.
Oddaljeno).
3. Set pilot arc High/Low switch. (Refer to cutting
3.
Nastavite High/Low stikalo pilotne iskre. (Oglejte si podatke
data in the torch manual.)
za rezanje v priročniku gorilnika.)
4.
Če uporabljate način kontrole s kontrolno ploščo, si ogljejte
4. If using panel mode, view preset amps with the
nastavljene vrednosti toka s stikalom ACTUAL/PRESET AMPS.
ACTUAL/PRESET AMPS switch. Adjust current
Nastavljajte tok, dokler vam ampermeter ne prikaže željene
until the approximate desired value is shown on
vrednosti. Če uporabljate oddaljen način, potem nastavitev
the ammeter.
Amps/Preset stikala v položaj Preset Amps prikaže začetni
5. Begin plasma cutting operation. This may
izhod, ki ga je nastavil oddaljen nadzor.
include manually setting up other options,
5.
Začnite rezanje s plazmo. To lahko vključuje ročne nastavitve
depending on the total plasma package.
drugih možnosti, odvisno od celotnega paketa orodja za
rezanje.
6. If using panel mode, after cutting has begun,
6.
Če uporabljate nadzor s kontrolne plošče, nastavite tok na
adjust current to desired amount.
željeno vrednost.
7. Check for fault light. If a fault light illuminates,
7.
V kolikor se proces rezanja ali označevanja ne prične, preverite
refer to troubleshooting section.
kontrolno lučko za napake. Če kontrolna lučka za napake sveti,
si oglejte poglavje o iskanju in odpravljanju napak.
Note: The fault light flashes when the contactor is
Note: The fault light flashes when the contactor is
Note: The fault light flashes when the contactor is
Note: The fault light flashes when the contactor is
first turned on signifying the DC Bus powered up
first turned on signifying the DC Bus powered up
first turned on signifying the DC Bus powered up
first turned on signifying the DC Bus powered up
normally.
normally.
normally.
normally.
Lučka za napake se na kratko vklopi ob prvem kontaktu stikala in tako
signalizira, da DC vodilo deluje normalno.
The time to achieve full current can be adjusted to
suit your particular system. This feature uses 50%
of the cutting current to start, dwell and then
gradually (less than a second) achieve full current.
The ESP-400C is factory shipped with this feature
enabled. The default settings are:
Minimum Start Current
239
Start Current
Timing to achieve full current
DELOVANJE
Operation
Opomba:
40A
50% of cut current
800 msec