3 SAFETY AND CONTROL DEVICES

SAFETY THERMOSTAT
The manufacturer will not be liable for any damage or in-
jury resulting from failure to observe the following rules.
• The appliance is equipped with a manual reset safety ther-
mostat which interrupts heating when the operating tempera-
ture exceeds the maximum permitted value.
• To restore appliance operation, press the thermostat reset
button. This procedure must only be carried out by a quali-
fied, authorized technician.

4 DISPOSAL OF PACKAGING AND THE APPLIANCE

PACKAGING
The packaging is made using environmentally friendly mate-
rials. The plastic recyclable components are:
• the transparent cover, the bags containing the instructions
manual and nozzles ( made of polyethylene - PE.).
• the straps (in polypropylene - PP).
APPLIANCE
The appliance is manufactured 90% from recyclable metals
(stainless steel, aluminum sheet, copper.... ).
The appliance must be scrapped in compliance with current
regulations governing such disposal.
• It must be disposed of properly.
• Make the appliance unusable before scrapping.

5 RISKS DUE TO NOISE

• As regards airborne acoustical noise emissions, the A-
weighted sound pressure level is below 70 dB(A).

INSTRUCTIONS FOR INSTALLATION

REMINDERS FOR THE INSTALLER

The manufacturer will not be liable for any damage or in-
jury resulting from failure to observe the following rules.
• Read this manual carefully. It provides important information
for safe installation, use and maintenance of the appliance.
• Installation, conversion to a different type of gas and applian-
ce maintenance must be carried out by qualified technicians
authorized by the manufacturer, in compliance with current
safety standards and the instructions given in this manual.
• Identify the specific appliance model. The model number is
detailed on the packaging and on the appliance data plate.
• The appliance must be installed in a well-ventilated room.
• Do not obstruct any air vents or drains present on the ap-
pliance.
• Do not tamper with appliance components.

6 REFERENCE STANDARDS AND LAWS

Install the appliance in compliance with current safety regula-
tions.
Install the appliance in compliance with current regulations.

7 HANDLING

The packaging is marked with warning symbols that indicate
the precautions to be taken when handling the appliance to
avoid damage.The appliance must only be handledusing su-
itable equipment. If lifting equipment is used, such as forklift
trucks or similar, make sure that the appliance is in a stable
position.

8 UNPACKING

Check the state of the packaging and in the event of damage,
ask the delivery person to inspect the goods.
• Remove the packaging.
• Remove the protective film from the exterior and interior pa-
nels. Use a suitable solvent to remove any residual adhesive
from the panels.

9 POSITIONING

• The overall dimensions of the appliance and the position of
connections are given on the installation diagram at the start
of this manual.
• The appliance can be installed singly or in combination with
other appliances in the same product range.
• The appliance is not suitable for integrated installation.
• Position the appliance at least 10 cm from adjacent walls.
This distance can be reduced in the presence of non-combu-
stible walls or heat-insulated walls.
9.1 APPLIANCE ASSEMBLY WITH BASE
Follow the instructions provided with the type of support utili-
zed.
JOINING APPLIANCES TOGETHER IN LINE
• Place the appliances side by side and adjust the tops to the
same height.
• Unite the appliances using the special unionjoint-coverings
supplied upon request

10 FUMES EXHAUST SYSTEM

Provide a fumes exhaust system based on the "Type" of ap-
pliance.The "Type" is stated on the appliance dataplate.
APPLIANCE TYPE "A1"
• Position the "A1" type appliance below an extractor hood to
ensure smoke and fumes generated by cooking are removed.
APPLIANCE TYPE "B21"
• Position the "B21" type appliance below an extractor hood.
APPLIANCE TYPE "B11"
• Fit the "B11" type appliance with a suitable flue, available
from the appliance manufacturer. Follow the assembly in-
structions provided with the flue.
• Connect the flue to a 150/155 mm diameter hose, heat resi-
stant to 300°C.
• Vent to the outside or into an efficient flue. The hose length
must not exceed 3 metres.

11 CONNECTIONS

The position and dimensions of connections are given in the
installation diagram at the start of this manual.
ELECTRICAL CONNECTIONS
Check that the appliance is designed to operate at the voltage
and frequency of the power supply present on site. Check the
details given on the appliance data plate.
If used, the symbol
indicates:
CAUTION - HAZARDOUS VOLTAGE.
5