Now it is possible to set up the time, the day of the week, the
date and the year, following the instructions.
1
Exact time
a) Push the line selection buttons to select line 1.
b) Push the
buttons to set up the time.
The time on the timer is set up according to the exact time.
This setting is important to ensure that the heating program
of the regulator will work correctly.
2
Day of the week (actual)
a) Push the line selection buttons to select line 2.
b) Push the
buttons to set up the day of the week.
The timer will be set on the selected day of the week.
1 = Monday
2 = Tuesday
3 = Wednesday
4 = Thursday
5 = Friday
6 = Saturday
7 = Sunday
3
Date (Day, Month)
a) Push the line selection buttons to select line 2.
b) Push the
buttons to set up the day of the week.
The day and month of the controller will be set at the actual
date. This setting is important to ensure a correct
Summer/Winter switching.
4
Year
a) Push the line selection buttons to select line 2.
b) Push the
buttons to set up the day of the week.
The year of the controller will be set at the actual year.
2.2.2
Installer Level
The configuration and set-up of the parameters must be carried out
by a heating engineer.
Among the possible display and set-up options there are:
– The recognized installation Type (53)
– The actual value of the cascade delivery temperature (55)
– The actual value of the cascade return temperature (57)
– The actual value of the D.H.W. temperature (59)
– The pursued cascade delivery temperature or setpoint of the
cascade delivery (66)
– The D.H.W. temperature setpoint (69)
– The environment temperature setpoint (70)
Please refer to Point 10 for a complete list of the parameters.
Buttons
Explanation
PUSH BOTH THE LINE SELECTION BUTTONS
FOR AT LEAST 3 SECONDS. THIS WILL LEAD
1
YOU DIRECTLY TO THE "INSTALLER
3s
PROGRAMMING MODE
PUSH THE LINE SELECTION BUTTONS
2
TO SELECT A LINE
PUSH THE "+/–" BUTTON TO SET UP
THE DESIRED VALUE. THE SET VALUE
3
WILL BE STORED WHEN YOU QUIT
THE PROGRAMMING MODE OR MOVE
ON TO ANOTHER LINE.
TO QUIT THE "INSTALLER" PROGRAMMING MODE
PUSH ONE OF THE BUTTONS OF
THE WORKING MODE.
4
If no button is pushed for 8 minutes,
the control device will return automatically
to the last selected working mode .
2.2.3
Manufacturer Level (OEM)
It is the level reserved to the boiler's manufacturer.
If we attribute the number 1 and 2 to the two "Prog" buttons
1
and the number 3 and 4 to the two buttons next to them,
3
the resulting access code will be: "1 2 4 3 4"
Please refer to Point 11 for a complete list of the parameters.
Buttons
Explanation
PUSH ONE OF THE " UP/DOWN" SELECTION
1
BUTTONS. THIS WILL LEAD YOU DIRECTLY TO
THE "END USER" PROGRAMMING MODE
9s
PUSH BOTH THE LINE SELECTION
2
BUTTONS FOR AT LEAST 9 SECONDS
PUSH THE
AND
THE REQUIRED ACCESS CODE. IF THE BUTTON
COMBINATION IS CORRECT YOU WILL SWITCH
TO THE OEM PROGRAMMING MODE. IF
3
CODE
THE INSERTED CODE WAS WRONG,
THE DISPLAY WILL SWITCH
TO "SETTINGS PARAMETER
FOR THE INSTALLER".
PUSH THE SELECTION BUTTONS
4
TO SELECT THE DESIRED LINE
PUSH THE "+/–" BUTTON TO SET UP
THE DESIRED VALUE.
THE SET VALUE WILL BE STORED WHEN
YOU QUIT THE PROGRAMMING
MODE OR MOVE ON TO ANOTHER LINE.
TO QUIT THE "OEM" PROGRAMMING MODE,
PUSH ONE OF THE BUTTONS OF
THE WORKING MODE.
6
If no button is pushed for 8 minutes,
the control device will return automatically
to the last selected working mode .
We highly recommend not to modify the OEM settings!
Line
51
51...... 1 99
2
4
Line
1
°°
BUTTONS TO INSERT
1..... 1 99
ES
ENG
FR
BE
33