drops under full load do not exceed 4% (10% during
start-up) compared with the rated voltage specified
on the data plate
- The operator must:
• fit a plug that respects the current regulations onto
the power supply cable;
• connect the machine to its own electrical connection -
A, Fig. 2 - and fit a differential safety circuit-breaker
with 30 mA residual current;
• install protection fuses on the power line that are
suitably sized in accordance with the indications
provided on the machine data plate (Fig. 1);
• connect the machine to an industrial socket; the ma-
chine must not be connected to domestic sockets.
An effective grounding connection is essential for correct operation of the machine.
Make sure the available pressure and the rendered capacity of the pneumatic system are
compatible with those required for correct machine operation - see the
"Technical Data" section. For the machine to operate correctly, the compressed air supply
must be capable of delivering air pressure within a range from 8 bar to 16 bar.
For correct equipment operation, the air produced must be suitably treated (not
above 5/4/4 according to ISO 8573-1).
Check that the lubricator cup (B, Fig. 2a contains
lubricant; top up if necessary. Use oil SAE20.
The compressed air supply delivery point in the
workshop must be equipped with a compressed
air supply shut-off valve located upstream of
the regulator/filter assembly supplied with the
machine (B Fig. 2a).
AS 924 - AS 924 A Operator's Manual