Additional Warnings - Deca CB BOOSTER Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
rifiuti delle apparecchiature elettriche ed elettroniche (RAEE) ed
all'attuazione del recepimento nel diritto nazionale, i prodotti
diventati inservibili devono essere raccolti separatamente ed
inviati ad una riutilizzazione ecologica.
Instruction manual
Automatic battery charger
Overview and warnings
Carefully read this manual, and both the instructions provided
with the battery and the vehicle in which it will be used before
charging.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
 To ensure protection against indirect contacts, connect only
to a suitable plug socket with earth.
 Never use the battery charger with a damaged mains lead
or plug.
 Never use the battery charger if it has been knocked, dropped
or damaged in any way.
 Never dismantle the battery charger: take it to an authorized
service centre.
 Supply cable must be replaced by qualified people.
 Never recharge frozen batteries.
 Never reverse the poles when connecting the clips to the
battery.
 For indoor use only.
< WARNING: EXPLOSIVE GAS!
< Batteries generate explosive gas (hydrogen) during normal
operation and even greater quantities during recharging.
< Avoid creating flames or sparks.
< The battery charger itself can generate sparks. Make sure
that the clamps cannot be accidentally released from the
battery's poles.
< Make sure that the plug is unplugged from the socket before
connecting or disconnecting the cable clamps.
< Never let the cable clamps touch each other.
< Provide adequate ventilation during charging.
< Whenever permitted by the type of battery, remove the caps
and check the level of the electrolyte in the cells, adding
distilled water if necessary. Make sure that the electrolyte
level is 5-0 mm over the battery's cells.
< Charge the battery with the electrolyte caps in place. Many
batteries have flame retardant caps. Place a damp cloth over
electrolyte caps that are not flame retardant.
< Carefully read the recharging instructions provided by the
Manufacturer for maintenance -free batteries.
< Never open the electrolyte caps in maintenance-free batteries.
EN
< Some maintenance-free batteries have level indicators.
Whenever the acid level is indicated as being too low, the
battery must be replaced. Never attempt to recharge such
batteries.
< Never charge frozen batteries that might explode.
< Never attempt to charge batteries that cannot be recharged
or other types than those indicated.
< Always wear safety goggles closed at the sides, acid-proof
safety gloves, and acid-proof clothing.
< Never position your face close to the battery.
< Position the battery charger as far as possible from the
battery
< Never let acid drip onto the battery charger, cables or clamps.

Additional warnings

< Never position the battery charger on flammable surfaces.
< Never place the battery charger and its cables in the water
or on wet surfaces.
< Position the battery charger with adequate ventilation; never
cover it with other objects or close it inside containers or
closed shelves.
Warnings for batteries in vehicles
< Maintain a safe distance from all moving parts, such as fans,
transmission belts and pulleys.
< Maintain a safe distance from all heated surfaces such as
engines and cooling systems to avoid burns.
Battery charger description
This automatic battery charger s designed to charge different
types of lead battery: flooded lead acid batteries requiring
maintenance or maintenance free (MF), GEL, AGM Ni-Cd
batteries.
i
Respect the instructions provided by the battery
Manufacturer for recharging.
Control and signal LEDs - Fig. 1

On-off switch

Protection fuse (,5AF 5x0mm)
3
Indicates that the thermostatic protection automatic reset
has cut in (the battery charger resets automatically)
4
Polarity reversal error (reverse the connections on the
battery clamps)
5
Indicates that at least one charge clamp is not connected
to the battery (check connection)
6
Indicates that 30 hours have passed and the battery is not
completely charged (probably a battery breakdown or the
charge current is regulated too low for the battery capacity)
the battery charger automatically turns off.
7
SET Ni-Cd - position used to charge nickel-cadmium
batteries
8
SET Pb-Gel - position used to charge lead batteries with gel
electrolyte
9
SET Pb-Wet - position used to charge lead batteries with
liquid electrolyte, including maintenance-free batteries
0 Indicates that the charge voltage selected does not
correspond to that of the battery being charged. WARNING:
there will also be a signal in the event the battery voltage is
very low. The battery recharge BLOCKS in this condition and
does not permit either Charge or START. See NOTE**
 Indicates the voltage selected for charging
 Charge position with automatic end of charge (the battery
5
Tabla de contenido