LUCCI AIRFUSION AIRLIE II ECO Serie Manual De Instrucciones De Instalación página 4

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
Airfusion Airlie II Installation Instructions
accordance with the wiring rules.
Example: If a fan is connected to a circuit that can be isolated via an
all-pole safety switch at the switchboard, then this is considered to be
an all-pole disconnection to the ceiling fan electrical circuit, meeting
the requirements of clause 7.12.2 of AS/NZS 60335.1.
A single-pole switch on the active of the receiver input of remote
control must also be included in the wiring, and located the
same room as the ceiling fan.
5.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local government for information regarding the collection systems available. If electrical
appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get
into the food chain, damaging your health and well-being.
6.
The structure to which the fan is to be mounted must be capable of supporting a weight of 30kg.
7.
The fan should be mounted so that the blades are at least 2.3 metres above the floor in Europe or 2.1 metres
above the floor in Australia.
8.
This fan is designed for indoor use only. Mounting the fan in a location where it is subject to water or moisture
is dangerous and will void the warranty.
9.
Only a licensed electrician should execute the installation.
4 | P a g e
Tabla de contenido
loading

Tabla de contenido