Connecting The Gas Console; Manual Gas Console Pcg-D; Automatic Gas Console Apgc - Cebora PLASMA PROF 180 HQC Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3.3

Connecting the gas console

3.3.1

Manual gas console PCG-D

• Secure the gas console above the power source or above the pantograph and connect the earths to an efficient
system based on the diagram in fig. 5.2 in the appendix.
Connect the pipe bundle Item No 1166, tightening the pipes to the respective gas output and ensuring the markings
match (plasma preflow/cutflow, secondary preflow/cutflow and auxiliary);
• tighten the electrical connector to the "VALVE CONSOLE" output (see left side of fig.3.7);
- connect the other end of Item No 1166 to the PVC valve console (Item No 469) for the "plasma", "secondary" and
"auxiliary" pipes, ensuring the markings match. Secure the PVC to the head of the pantograph, near the torch (see
right side of fig. 3.7);
• lastly, connect connection Item No 1189 tightening the electrical connector to the "POWER SOURCE" output (see
left side of fig. 3.7).
Fig. 3.7
3.3.2

Automatic gas console APGC

• Secure the gas console above the power source or above the pantograph and connect the earths to an efficient
system based on the diagram in fig. 5.2 in the appendix.
• Connect the pipe bundle Item No 1166 tightening the pipes to the respective gas outlets and ensuring the markings
match (plasma preflow - cutflow, secondary preflow - cutflow and auxiliary); tighten the electrical connector to output
CN05 (see fig.3.8).
• Connect the other end of Item No 1166 to the PVC valve console (Item No 469) for "plasma", "secondary" and
"auxiliary" pipes, ensuring the gas pipe markings match. Secure the PVC to the head of the pantograph, near the torch
(see right side of fig. 3.7).
100/128
3.8
Fig.
Tabla de contenido
loading

Este manual también es adecuado para:

Plasma prof 300 hqc968969

Tabla de contenido