Section 6
Page 24
Fault
If an error occurs, the regeneration will be interrupted and an error message displayed on the display. The
red LED flashes.
The following table shows the possible faults and their solution:
Figure 5
The following table shows the possible faults and their solution:
Fault
SENSOR BREAK
SENSOR SHORT CIRCUIT
IBUTTON FAULT
TEMPERATURE OF THE
INTERIOR
I2C BUS
EEPROM DEFECT
REAL TIME CLOCK DEFECT
IO-MODULE DEFECT
FAULT OF THE GENERATOR
G1
FAULT OF THE GENERATOR
G2
FAULT OF THE GENERATOR
G3
FAULT OF THE GENERATOR
G4
NO REG.- PROGRAM
ERROR REG-PROG
Induction trolley
ITW
Possible cause
The regeneration program is already
completed
Fault indication on the display of the control panel
Possible cause
Sensor is defect or disconnect-
ed
Sensor short-circuited
No reaction of the i-button
driver
The inside temperature is too
high
Hardware failure
Hardware failure
The real time clock does not
react
The IO module does not re-
spond
Generator 1 reports faults
Generator 2 reports faults
Generator 3 reports faults
Generator 4 reports faults
i-button contains no menu data
Regeneration data not read
correctly (i-button)
Troubleshooting and Repair
Fault and Action Table
Action
Wait until the next Auto Start
Action
Switch off the induction trolley
and inform a technician
Switch off the induction trolley
and inform a technician
Switch off the induction trolley
and inform a technician
Confirm with SET, adjust settings
Switch off the induction trolley
and inform a technician
Switch off the induction trolley
and inform a technician
Switch off the induction trolley
and inform a technician
Switch off the induction trolley
and inform a technician
Confirm with SET when error message comes
back after 5 minutes, turn off the induction trol-
ley, and notify a service technician
Confirm with SET when error message comes
back after 5 minutes, turn off the induction trol-
ley, and notify a service technician
Confirm with SET when error message comes
back after 5 minutes, turn off the induction trol-
ley, and notify a service technician
Confirm with SET when error message comes
back after 5 minutes, turn off the induction trol-
ley, and notify a service technician
Reload the program menu (menu manager /
service mode)
Reinstall the i-button, reload the program on i-
button, reload on BG
91249668_A2