Maintenance And Cleaning - Abicor Binzel ABICUT 25K Instructivo De Servicio

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ABICUT 25K/45/75
2 Switch off the power source.

9 Maintenance and cleaning

Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free
operation.
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance, servicing,
assembly, disassembly and repair work:
• Switch off the power source.
• Close the gas supply.
• Close the compressed air supply.
• Disconnect all electrical connections.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
WARNING
Risk of burns
The welding torches reach very high temperatures during welding.
• Allow the welding torches to cool down.
• Wear the correct protective gloves.
NOTICE
• Maintenance and cleaning work must only be carried out by qualified personnel (in
Germany, see TRBS 1203).
• Always wear your personal protective equipment when performing maintenance and
cleaning work.
• Remove any adhering weld spatter.
1 Check that all threaded fittings are tight and inspect wear parts for visible damage. Replace
if necessary.
2 The electrode must be replaced if the weld penetration is deeper than 1.5 mm.
3 Clean the cutting torch body regularly to remove cutting spatter.
BAL.0173 • 2018-09-28
9 Maintenance and cleaning
EN - 13
Tabla de contenido
loading

Este manual también es adecuado para:

Abicut 45Abicut 75Abicut 75 hf

Tabla de contenido