ENGLISH
The ceramic cooker is equipped IN STANDARD
with RESIDUAL HEAT INDICATOR LIGHT on
the cooker, which indicates that temperature of
the cooking surfaces exceeds 70°C and warns the
user to NOT TO TOUCH the cooking surfaces to
avoid burns. The indicator light becomes on after
few minutes from the activation of cooker heating
coils and remains on during the normal operation.
After deactivation of the heating plates it remains
on until the temperature drops below 50°C.
Keep in mind that in case of sudden
power supply failure there is the risk of
burns as the cooking surfaces may be still
hot.
GB
5.
USE AND OPERATION
5.1.
Description of the use the
The elements controlling the essential functions
are located on the control panel of the device.
A) Temperature controller: adjusts power
of electric heating plates
B) Oven thermostat controller: adjusts
temperature of the electric oven
C) Oven switch: activates upper, lower, or
both heating coils.
D) Green indicator light: indicates activated
power supply
Front heating
plate position
A
Plate power
device.
Maximum
Back heating
power
plate position
position
D
Supply voltage
indicator light
Check every day that the protection
devices are mounted correctly and
operational.
E) White indicator light: indicates oven
heating
F) Red indicator light: indicates activation of
safety thermostats.
G) Indicator light of heating plates:
indicates activation of electric heating
plates.
A
6
G