Start Up
P-T chart
CAUTION!
Back pressure valves may fail earlier than expected.
The pressure and temperature of the feed chemical must be below the corresponding
curve.
The pressure-temperature chart (P-T chart) gives guideline values for the material resistance of the
various material versions for feed chemicals against which the back pressure valves are resistant.
Consult ProMinent for other cases.
P [bar]
10
9
8
7
6
5
4
3
2
1
-50 -40
-30 -20 -10
Fig. 4: Pressure/temperature chart
P
Pressure (bar)
T
Temperature (°C)
46
PVC-U
PP
0
10
20
30
40
T [°C]
PVDF, SS
50
60
70
80
90 100 110
P_MAZ_0038_SW