Arneg Francoforte Serie Guía De Instalación Y Manejo página 52

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 100
F r a n c o f o r t e
English
The cabinet
• the cabinet is in defrosting
phase
does not cool
• air inlets are obstructed
sufficiently
• the load is not distributed even-
ly
• the cabinet is next to air cur-
rents or heat sources
• the cabinet is not levelled
• evaporator frozen
The engine is
• screws and bolts are not tight-
noisy
ened
• the cabinet is not levelled
Condensate
• poor room conditions
• poor air ventilation
• the window heaters do not work • check electrical connections
• the windows are not closed
properly
Cabinet
• poor room conditions
temperature
is too high or
• o u t p u t a i r t e m p e r a t u r e i s o u t -
too low
side the specified range
• the cabinet is defrosting.
• the capacitor or the evaporator
are freezing.
• the capacitor or the evaporator
are obstructed or dirty.
• the load is not distributed even-
ly
Water leaks,
• cabinet drains are obstructed or
bad smell
damaged
• water collection tray is sealed
incorrectly
• water collection tray overflows • check wiring of evaporation heater
• lacking coupling between cabi-
nets in channel or sealed incor-
rectly
Frost or ice
in the cabinet
• fans do not work
in the evaporator
• heating elements broken
• Sdef probe detached
• air currents that alter the circu-
lation of refrigerated air
i
in all cases not described or where it is not possible to solve the problem by following these
directions call the nearest authorised after-sales centre.
4 8
• wait for defrosting to complete (about 30min)
• r e l e a s e a i r i n l e t s
• load the goods in order (Fig.14)
• check the position of the cabinet inside the
store chap.13
• level the cabinet see chap.13
• thaw it
• tighten the bolts and screws
• level the cabinet chap.13
• check the position of the cabinet inside the
store chap.13
• check the operation of fans and wiring
• check the operation of heating elements
• close the windows properly
• check the position of the cabinet inside the
store chap.13
• check the operation of evaporator fan
• check wiring and input voltage
• the fans are installed reversely; check and re-
store the air flow direction
• check that fan plenum is sufficient and not
obstructed
• check the intake pressure that should comply
with rated specifications
• check defrosting parameters
• check that the suction line is not obstructed
• proceed with cleaning
• load the goods in order (Fig.14)
• clear the drains
• repair or replace the drains
• seal it properly
• check the operation of evaporation heater
• install and seal the joints
• check electrical connections
• check the ventilation inside the store
05060171 00 13-02-2018
Tabla de contenido

Solución de problemas

loading