Install Electrical Connection
Connect Electric
WARNING
,
To prevent electrical shock, the grounding prong on
the range cord should not be cut or removed under
any circumstances. It must be plugged into a match-
ing grounding type receptacle and connected to a
correctly polarized 240- Volt circuit. If there is any
doubt as to whether the wall receptacle is properly
grounded, have it checked by a qualified electrician.
WARNING
,
Risk of Electric Shock or Fire. Frame grounded to
neutral through a ground strap. Grounding through
the neutral conductor is prohibited for new branch-
circuit installations (1996 NEC), mobile homes, and
recreational vehicles, or in an area where local codes
prohibit grounding through the neutral conductor.
For installations where grounding through the neu-
tral conductor is prohibited,
(a) disconnect the link from the neutral,
(b) use grounding terminal or lead to ground unit,
(c) connect neutral terminal to lead branch circuit
neutral in usual manner
(when the appliance is to be connected by means of
a cord kit, use 4-conductor cord for this purpose)
Use only cord kits rated 125/250 volts (minimum),
50 amperes and labeled "For Use with Ranges".
Strain relief provided with cord must be installed per
instructions included with cord.
Four Wire Range Cord Connection
(Recommended Method)
1. Disconnect electrical power at breaker box.
Remove the terminal block cover to expose the
terminal block.
8
2. Remove top nut, star washer, and round washer
from each post.
Note: DO NOT remove last round washer, last nut or
internal wiring leads.
3. Remove screw from bottom end of ground strap.
4. Remove ground strap from center post, rotate so
that wide end is at top and attach wide end to
range through hole below junction box. Attach
green wire on top of ground strap. Tighten Screw.
ground strap
5. Attach red wire, round washer, star washer and
nut IN THIS ORDER to left post.
6. Attach white wire, round washer, star washer and
nut IN THIS ORDER to center post.
7. Attach black wire, round washer, star washer and
nut IN THIS ORDER to right post.
red
8. Tighten all connections securely and replace ter-
minal block cover.
9. Properly secure strain relief (see previous sec-
tion).
Note: DO NOT plug in range at this time.
green ground screw
ground wire
black
white