Preparation; Cabinet Requirements - Bosch 40 Instrucciones De Instalación

Estufa eléctrica independiente
Ocultar thumbs Ver también para 40:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Preparation

Parts provided:
• Anti-Tip Bracket
• 2 wood screws
• 2 anchorless concrete screws
• Foam Tape
• Terminal Lugs (For Use With Hard Wire
Installations)
Note: not necessary for Canadian installations
Tools and parts needed:
• 50 Amp Power Supply Cord Kit (not necessary for
Canadian installations)
• Measuring Tape
• Phillips Head Screwdriver
• 1-4" Wrench
• Pencil
• T-20 Torx Screwdriver
• Screws (2) and Anchors (2) for Anti-Tip Bracket
(Style will vary depending on mounting surface)
• Level
• Drill and Drill Bit (3/16" masonry bit for
concrete screws)
• Safety Gloves and Goggles
• Tape (Optional)
• Cloth or Cardboard (Optional - to Protect Floor)
Additional Parts Needed For
Hard Wire Installations
• Flexible Conduit (For Hard Wire Installation Only)
• Torque Wrench (For Hard Wire Installation Only)
Note: Power Supply Cord Kit Not Necessary For
Hard Wire Installations

Cabinet Requirements

This unit is designed for installation near adjacent
walls and projecting surfaces constructed of com-
bustible materials. Allow a minimum of 30" (76.2 cm)
between cabinets where range is to be installed
(0.47" (12 mm) clearance from range sidewall to
cabinet required in Canada).
30" (76.2 cm) Minimum
between cabinets
Required Clearances:
These clearance instructions were determined using
Standard American cabinets. Standard base cabinets
measure 36" (91.4 cm) high x 24" (61 cm) deep.
Cabinets over the cooking surface and cabinets adja-
cent to those over the cooking surface measure 13"
(33 cm) deep from backwall. If nonstandard cabinets
are used, care should be taken to alter dimensions
accordingly.
Note: Some cabinet inishes cannot survive the tem-
peratures allowed by U.L.for appliances, particularly
self-cleaning ovens; the cabinets may discolor or
stain.
This is most noticeable with laminated cabinets.
From cooktop to materials above:
There must be a minimum clearance of 30" (76.2 cm)
between the top of the cooking surface and the bot-
tom of an unprotected wood or metal cabinet.
24" (61 cm) is acceptable when the bottom of the
wood or metal cabinet is protected by
(a) not less than 4" (6.4 mm) of lame retardant
material which must be covered with
(b) not less than No. 28 MSG sheet metal, 0.015"
(0.4 mm) stainless steel' or 0.024" (0.6 mm)
aluminum or copper.
From range walls to adjacent materials:
No clearance is required from unit walls to adjacent
vertical combustible walls on rear, right or left.
Clearance from range top to adjacent vertical walls
must be at least 4" (10.2 cm).
30in (76.2 cm )
min. centered
30in (76.2 cm) min.
4in (10.2 cm )
min
no clearance required (12 mm clearance from
range sidewall to cabinet required in Canada.)
4in (10.2 cm)
min
5
Tabla de contenido
loading

Este manual también es adecuado para:

50

Tabla de contenido