Analyzer Functions - Amprobe MultiTest 2000 Manual De Usuario

Ocultar thumbs Ver también para MultiTest 2000:
Tabla de contenido
AMPROBE
8.3.

ANALYZER FUNCTIONS

For a simple usage, the main working mode of the ANALYZER mode can be
selected by means of F3 and F4.
"VOLTAGE" function:
"CURRENT" function:
"POWER" function:
"ENERGY" function:
More practically, we may schematise the right procedure of use the ANALYZER function
as follows:
1. Check and eventually modify the "ANALYZER CONFIG" settings of the instrument
2. Using F3 and F4, select the type of measurement to be taken
3. Connect the instrument to the electrical system to be tested
4. Evaluate the values of the parameters under test
5. If you want to record:
a) Decide what to record
b) Press MENU and check if the "RECORDER CONFIG" settings meet your
requirements
6. Connect the External Power Supply A0050 (optional)
7. Start the recording by pressing START/STOP.
to be used to display voltage and corresponding
harmonics (see paragraph 8.4)
to be used to display current and corresponding
harmonics (see paragraph 8.5)
it permits to display all the parameters measurable by
the instrument: voltage, current, active, reactive and
apparent power, power factor, cosϕ and energy (see
paragraph 8.6)
to be used to display active, reactive and apparent
power, power factor, cosϕ and energy (see paragraph
8.7)
MULTITEST2000

Capítulos

Tabla de contenido
loading

Tabla de contenido