17.2 - PARAMETERS TRAVEL PERCENTAGE)

Some parameters of the programming menu are based on a
percentage of the total travel of the door.
m
ATTENTION: to use these parameters it is necessary to carry
out the learning procedure of the travel.
According to the configuration of these parameters the following
operations can be controlled:
1. Start of slowdown
• During the opening phase the slowdown starts when the
door reaches the final part of the travel: such a final part is
determined by a percentage of the total travel and is set using
the parameter
RAL.A
• During the closing phase the slowdown starts when the
door reaches the final part of the travel: such a final part is
determined by a percentage of the total travel and is set using
the parameter
RAL.C
2. Partial opening position
The partial opening operation ends when the door exceeds the
percentage of travel set by the parameter

18 - ENCODER

The position of the door can be detected much more accurately if
an incremental decoder is mounted on the motor.
m
WARNING: It is essential to run the learning phase of
the travel (chapter 26.3) to use this feature
NOTE: The encoder uses the same terminals of the switches for
the intermediate positions. If you are using an encoder you cannot
use the switches for intermediate positions.
It is possible to use two types of encoder:
• Two-channel encoder: the direction of movement of the door is
indicated by the encoder itself.
- Connect the two channels on terminals H3 and H4
(the connection order is not important)
- Connect the common on the terminal H5
- Set the menu
on
ENCO
• One-channel encoder: the direction of movement is
determined by the command given to the inverter through the
unit.
- Connect the channel of the encoder on terminal H4
- Connect the common on the terminal H5
- Set the menu
on
ENCO
If the encoder is powered to 24Vac connect the power supply to
terminals E1 and E3.
If the encoder is powered to 12Vdc connect the power supply to
terminals H7 (-) and H8 (+).
* NOTE: if the encoder has a single wire for the negative pole
of the power supply and the common of outputs, connect the
terminal H5 to the negative pole of the power supply
(terminal H7 or one of the terminals E1-E3)
P.APP
EN.2C
EN.1C
H1H2 H3 H4 H5 H6 H7 H8 E1 E2 E3 E4 E5
ENCODER
2C
H1H2 H3 H4 H5 H6 H7 H8 E1 E2 E3 E4 E5
ENCODER
2C
H1H2 H3 H4 H5 H6 H7 H8 E1 E2 E3 E4 E5
ENCODER
1C
H1H2 H3 H4 H5 H6 H7 H8 E1 E2 E3 E4 E5
ENCODER
1C
parameter
ENCO
- 39 -
24Vac
-
12Vdc
+
24Vac
-
12Vdc
+
a
DEFAULT =
(no function)
NO