20 - REMOTE CONTROL MODE

The HEAVY1 unit is fitted for the connection of an MR series
receiver. The receiver has 4 channels, which can be associated
with the buttons on the remote control and can have the
following functions:
• Channels 1 and 2 trigger the opening cycle according to the
setting of the parameter
RX
: channel 1 is equivalent to START command and
START
channel 2 to PARTIAL START command
: channel 1 is equivalent to the command OPEN and
APCH
channel 2 to the command CLOSE
• Channel 3 is equivalent to the STOP command
• Channel 4 operates according to the setting of the
parameter
:
AUX
: monostable. The contact of an option relay (REL1-2-3)
MON
set as courtesy light is kept closed as long as the channel is
active.
: bistable. The contact of an option relay (REL1-2-3)
BIST
set as courtesy light is switched every time the channel is
activated.
: timer. The contact of an option relay (REL1-2-3) set as
TIM
courtesy light is kept closed for the time set. If the channel is
again activated, the time count is reset.
: time out. The contact of an option relay (REL1-2-3)
TOUT
set as courtesy light is kept closed for the set time.
If the channel is again activated, the relay contact is opened.
: force dead man mode. At each activation of the
PRES
channel the unit switches between the operating mode
set and the dead man mode.

21 - OPERATING MODES

The operating mode of controls depends on the settings of the
parameter MODE.
• Pulse mode (
=
MODE
STAN
A command opens the door.
The manoeuvre ends when the limit switch is activated,
when another command is received or when a safety device
is activated. When the automatic closing is enabled the door
closes after the pause time set (parameter
• Clock mode (
=
MODE
CLOCK
This function allows to delay the opening of the door through
an external clock.
The operation is identical to the mode
time count is suspended until the contact of the device
connected to an input configured as
is closed.
APRE
To use this feature, you must enable the automatic closing
(parameter
)
CH.AU
• Dead man mode (
MODE
The command must be kept active for the entire duration of
the movement of the door; when the command is
suspended the door stops immediately. In this mode, the
START command launches alternately the opening and
closing.
• Mixed mode (
=
MODE
S.PRE
The opening movements are controlled by pulses and the
closing ones in dead man mode.
A door that moves in dead man mode stops if a safety device
is activated; it is not possible to reverse the movement of the
door as during normal operation.
:
)
)
CH.AU
)
, but the pause
STAN
,
or
STRT
ST.PE
=
)
PRES
)

22 - SPECIAL OPERATING MODES

The HEAVY1 unit has some special operating modes, to be used
only in special cases.
Dead man mode
The dead man mode can be temporarily forced through a
command on terminal S3: when the contact is closed, the mode is
activated (the parameter
Emergency dead man mode
If a command is rejected because of an active safety device,
holding the command active for 5 seconds, the unit activates the
dead man mode, and the door moves as long as the command is
maintained.
When the command is suspended the unit returns to the mode
set.
In this way it is possible to move the door when there is evidence
of a fault on a safety device.
m
WARNING: during the emergency movement the safety
device considered defective is not taken into account: all its
activation will be ignored

Manual handling

During installation or maintenance, you can move the door
h
through the buttons
The operation mode is always dead man:
h
i
opens and
closes the door.
The speed of the door is determined by the value set for the
parameter
VEL.M
m
WARNING: all the safety devices are ignored
(except for the Emergency STOP), then it is the operator's
responsibility to make sure that there are no obstacles on
the travel path of the door.
During manual handling, the display shows some information on
the operation of the inverter: voltage, current on the motor and
temperature of the driver.
Inv: 298V
NOTE: It is possible to read this information without moving the
door with a quick pressure on one of two
The manual handling mode remains active for 1 minute, then the
unit returns to normal operation.
To immediately return to normal operation, press the OK button
for 1 second.