Electric Connections - V2 HEAVY1 Manual De Instrucciones

Cuadro de maniobras digital 230v con inverter para motores trifásicos
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

8 - ELECTRIC CONNECTIONS

TOP BOARD
Antenna shielding
A1
Antenna
A2
ING1 - configurable input to connect devices with
N.O. contact
S1
parameter
ING1
DEFAULT =
START
ING2 - configurable input to connect devices with
N.O. contact
S2
parameter
ING2
DEFAULT =
ST.PE
ING3 - configurable input to connect conventional
devices with N.O. contact
S3
parameter
ING3
DEFAULT =
(no function)
NO
Common (-)
S4
Photocell 1. N.C. contact
S5
parameter
FOT1
DEFAULT =
(no function)
NO
Photocell 2. N.C. contact
parameter
S6
FOT2
DEFAULT =
APCH
closing)
Safety ribb. 1. N.C. contact
S7
parameter
COS1
DEFAULT =
(no function)
NO
Safety ribb. N.C. contact
S8
parameter
COS2
DEFAULT =
(no function)
NO
Common (-)
S9
Closing limit switch. N.C. contact
H1
Opening limit switch. N.C. contact
H2
- Channel 1 encoder
- Intermediate position switch
H3*
parameter
ENCO
DEFAULT =
(no function)
NO
- Channel 2 encoder
- Intermediate position switch
H4*
parameter
ENCO
DEFAULT =
(no function)
NO
Common (-)
H5
- Open door warning light
- 24Vdc blinker
H6**
parameter
SPIA
DEFAULT =
(open door warning light)
W.L.
- Common open door warning light
H7
- 12Vdc common power supply
12Vdc power supply
H8
24Vac accessory power supply
E1 / E2
Common accessories power supply
E3 / E4
Photocell TX power supply (24Vac) for Functional test
E5
Emergency STOP
T1 - T2
(activates the cycle)
(partial opening)
(enabled when opening and
LOWER BOARD
MOTOR
Motor
U3-U2-U1
REL3 relay options (16A - 250V)
BRAKE
REL3
B2-B1
DEFAULT =
motor is running)
REL2 relay options (5A - 250V)
OUTPUT
Z6-Z5
REL2
DEFAULT =
REL1 relay options (5A - 250V)
OUTPUT
parameter
REL1
Z4-Z3
DEFAULT =
OUTPUT
230V - 40W blinker
Z2-Z1
Mains power supply 230V - 50Hz
N - L
Ground terminal for connection of the ground
W
G1 - G2
system and the motor
OTHER
T315mA. Power fuse
F1
F16A. Motor inverter fuse
F2
ADI interface
ADI
MR receiving modules
RECEIVER
It indicates a 24Vac power overload of
OVERLOAD
accessories
POWER
It indicates that the control unit is powered
LOGIC
POWER
It indicates the inverter driving the motor is
MOTOR
powered
GREEEN LED
Flashes when the inverter driving the motor is in
OK
stand-by
Turned on and fixed when the motor is running
YELLOW LED
Flashes when the power supply of the inverter
ATTENTION
driving the motor is charging
Turned on and fixed when the emergency STOP
is on
RED LED
ERROR
Turned on and fixed when a fault of the encoder
is detected
- 30 -
parameter
(contact closed when the
FR.NO
parameter
(no function)
NO
(courtesy lights)
LUCI
Tabla de contenido
loading

Tabla de contenido