Blinker; Open Door Warning Light; External Antenna - V2 HEAVY1 Manual De Instrucciones

Cuadro de maniobras digital 230v con inverter para motores trifásicos
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

13 - BLINKER

The HEAVY1 unit has two outputs for the management of the
blinker:
1. Z1 and Z2 terminal for a 230V - 40W blinker with internal
intermittence
2. H6 (+) and H7 (-) terminals for a 24Vdc - 3W blinker.
Using a 24V blinker you need to set the
the value
(DEFAULT =
FLASH
NOTE: If these terminals are used for this function it will not
be possible to connect a open door warning light.
H1H2 H3 H4 H5 H6 H7 H8
+
-
24Vdc - 3W
The normal operation of the blinker involves its activation during
both opening and closing of the door.
The other options available are:
• Enabled blinker set to pause: you need to set the value
the parameter
LP.PA
• Pre-flashing: the blinker is activated before the beginning of
the opening and closing phases for a time that can be set via
the parameter
T.PRE
• Pre-flashing during closing: the blinker is activated before the
closing phase for a time other than that set for opening.
The time can be set via the parameter
parameter with
SPIA
).
W.L.
Z6
Z5
Z4
Z3
Z2
Z1
OUTPUT
230V - 40W
SI
T.PCH

14 - OPEN DOOR WARNING LIGHT

The unit is fitted with a 24Vdc - 3W output that allows the
connection of a warning light.
The open door warning light shows in real time the status of the
door, the type of flashing indicates the four possible conditions.
- DOOR STOPPED (CLOSED): the light is off
- DOOR IN PAUSE MODE (OPEN): the light is on and fixed
- OPENING DOOR: the light flashes slowly (2Hz)
- CLOSING DOOR: the light flashes fast (4Hz)
Connect the cables of the warning light to terminals
H6 (+) and H7 (-)
NOTE: if these terminals are used for this function it will not be
possible to connect a 24Vdc blinker
parameter a DEFAULT =
SPIA

15 - EXTERNAL ANTENNA

for
To guarantee the maximal radio range radio it is advisable to use
the external antenna.
Connect the shield of the antenna to the terminal A1 and the hot
pole to the terminal A2.
- 37 -
H1H2 H3 H4 H5 H6 H7 H8
+
-
24Vdc - 3W
(open door warning light)
W.L.
A1A2
Tabla de contenido