OPENING/CLOSING CYCLE PHASES
1. Acceleration ramp
2. Regular operating speed
3. Slowdown
4. Slowing ramp
5. Braking
10 - EMERGENCY STOP
For added security it is OBLIGATORY to install a STOP switch that
when pressed will immediately block automation.
The switch must have a normally closed contact, which opens in
case of activation.
NOTE: terminals T1 and T2 are connected to allow start of
automation before connecting the STOP switch.
Connect the cables of the STOP switch between terminals
T1 and T2 of the unit.
m
CAUTION: if the STOP input is not used, the terminals
T1 and T2 must be bridged.
5-FRE.A
4-DEC.A
3-VE.RA
2-VEL.A
1-ACC.A
OPENING (parameters to be programmed)
ACC.A
VEL.A
VE.RA
DEC.A
FRE.A
- 33 -
CLOSING (parameters to be programmed)
ACC.C
VEL.C
VE.RC
DEC.C
FRE.C
E1 E2 E3 E4 E5
T1 T2
1-ACC.C
2-VEL.C
3-VE.CH
4-DEC.C
5-FRE.C