5.1 - ELECTRIC CONNECTIONS
m
WARNING: The installation of the unit, safety
devices and accessories must be carried out when the
power supply is disconnected
BEFORE PROCEEDING WITH THE ELECTRICAL
CONNECTIONS, READ CAREFULLY THE CHAPTERS
DEDICATED TO THE INDIVIDUAL DEVICES AVAILABLE IN
THE PAGES THAT FOLLOW.
L1
Centrale antenna
L2
Antenna shielding
L3
START - Opening control for the connection of
control devices with N.O. contact
L4
START P. - Opening controls for pedestrian access for
the connection of control devices with N.O. contact
L5
STOP - Stop command. N.C. contact
L6
Common (-)
L7
COSTA - Safety edge
L8
FOTO - Photocells. N.C. contact
L9
FCA - Open limit switch
L10
FCC - Close limit switch
L11
Common (-)
Z1
Power output 24 Vac for photocells and other
accessories
Z2
Common for accessories power supply
Z3
Photocell/optical edge TX power supply for
functional test
Z4 - Z5
Lock 12V
Z5 - Z6
Low voltage light (12Vdc - 3W)
G1 - G2
G3
G4
G5
G6 - G7
L
N
Encoder
RM
ADI 2.0
USB
OVERLOAD
MAINS
F1
J1 - J2 - J3
- 32 -
Courtesy light. N.O. contact
Motor (OPENING)
Motor (COMMON)
Motor (CLOSING)
Flashing light 230V - 40W
Power phase 230V / 120V
Neutral 230V / 120V
MR receiving modules
ADI 2.0 interface
USB connector
It shows that there is an overload on accessories
power supply
It shows that the control unit is power supplied
5 A (230V versions)
8 A (120V versions)
Connectors for the LOW ENERGY module