Cleaning And Maintenance; Technical Specifications - Novellini STOCKOLM Manual De Instalación, Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
• During pregnancy.
• During the menstrual cycle (risk of haemorrhage)
• If you are still growing
• If you are under the effect of alcohol, strong medicines or
drugs.
WHY YOU SHOULD TAKE A SAUNA:
It has a relaxing effect on muscles and a pain-killing action. As
it removes dead cells, the skin becomes more luminous and
elastic and offers greater resistance to atmospheric agents.
It improves the blood and lymphatic circulation. It is
particularly suitable for athletes as it helps recovery, speeding
up the digestion of toxins and lactic acid.
A sauna does not have a slimming effect; weight lost during
a session is linked to the loss of fluids which will be recovered
by drinking after coming out of the sauna.
WARNINGS:
• Never hang clothes inside the sauna, as they could be a fire
hazard.
• Do not touch the heater when it is hot as it could cause
burns.
• Before using it, consult your doctor about the risks the sauna
could cause for your health.
• Never put water in the sauna and, if it should happen, make
sure you dry it immediately.
• When you throw water onto the stones, be extremely careful
as the steam released could cause burns!
CLEANING THE SHOWER UNIT:
Sauna compartment maintenance:
The sauna box is made of untreated wood.
As it is a natural fibre, after several sessions, cracks may
appear. As these are linked to the natural aging of the wood,
they are not considered harmful either for the structural
integrity or the correct operation of the sauna.
We recommend towels are used to protect the wood from
sweat. When necessary, the wood surface should be cleaned
using a product designed specially for saunas.
To clean the floor and the stove, remove the dirt and dust
then wipe with a damp cloth.

CLEANING AND MAINTENANCE:

The cubicle panels are made with acrylic parts and must be
cleaned using a liquid detergent and a soft cloth or sponge.
Use a good quality household liquid detergent. To prevent
scale deposits, wipe dry using a chammy leather or a soft lint-
free cloth that removes stubborn deposits without leaving
traces. Limescale deposits may be removed using specific
detergent products. To restore shine to the acrylic surface
polish with an ordinary wax polish such as car wax. DO NOT
USE ABRASIVE CLEANERS, ALCOHOL OR ALCOHOL BASED
PRODUCTS, ACETONE OR OTHER SOLVENTS.
Dismantling the shower valves:
In the event of the formation of lime scale and a resulting
malfunctioning of the shower valves, dismantle the parts
(fig. A, B, C...). We recommend you immerse the cartridge in
normal vinegar until it is completely lime scale-free.
PRODUCT GUARANTEE:
All products purchased by consumers, as defined in Article
3 of the Consumer Code (Legislative Decree no. 206 of 6
September 2005 and subsequent amendments), are covered
by the legal guarantee of the seller under Article 128 and
subsequent amendments of the consumer Code. In case of
lack of conformity of the product, we invite the consumer to
contact their dealer within the statutory deadline.
WATER TREATMENT
• The hardness of the domestic water supply affects the
operation and the cleaning frequency of the thermostatic
mixer and boiler unit.
• In case of water with hardness above 15°f an antiscale device
is recommended. The choice of device should be made
according to the characteristics of the water supply.
This symbol indicates important product instructions
or important safety information.
INSTALLATION INSTRUCTIONS:
IMPORTANT:
Before you start to assemble and install the product, carefully
read through all the instructions. Unpack the components
and check that nothing is missing and that there are no
damaged or faulty components, remove the transparent
protective film. Before you install the shower cubicle in its
final position, perform a test run. Run the unit for several
minutes and check for water leaks and any damage caused
during transport and handling. This product should be
installed by suitably skilled personnel.
To ensure correct operation of the thermostatic mixer, the unit
must be supplied from a boiler or a water heater providing 6
to 7 litres per minute of water at a temperature of 60/65°C. If
an instantaneous gas water heater is used, this must be of the
modulating flame type. The water supply pressure from the
boiler must be from 2 to 5 bar.
N.B.: This product is designed for installation on finished walls
and floors.
Warranty claims must be produced with the purchase invoice
and the product assembling instructions.
The drawings and illustrations in this manual are provided for
information purposes only.
The manufacturer reserves the right to make changes and
improvements without prior notice.
For the guarantee to be valid, the product must be installed
as supplied by the manufacturer, in compliance with the
installation standards indicated below and according to the
data sheet.
ELECTRICAL CONNECTION:
The manufacturer hereby certifies that the product conforms
to current health and safety regulations at the time of sale
and that the product has the CE-mark and Declaration of
Conformity. All products and components are tested during
manufacture in accordance with the relevant reference
standards and company quality system procedures. In order
to ensure that your manufacturer product maintains these
high standards after installation and throughout its service
life, please read the following instructions.
1. Check that the mains electrical equipment connected
to cubicle conforms to current electrical standards and
regulations and is fitted with a fully efficient earth connection.
2. Check that rating of the mains power supply line matches
the absorbed power specified for the cubicle (see Technical
specifications pag. 4).
3. The electrical connection between the cubicle and the
mains must be protected against water spray and must have
a protection rating of IP55 or higher.
4. The electrical equipment upstream from the cubicle must
be fitted with an omnipolar 30 mA switched circuit breaker
with a minimum contact opening of 3 mm, which conforms
to current electrical regulations.
5. In addition, if the product is installed in the bathroom,
the standard requires the omnipolar circuit breaker (I) to be
placed outside areas 0,1,2,3 (see figure 1).
6. The heating element has a mass terminal which must be
connected to the auxiliary equipotential earth connecting all
the metal components in the bathroom
21).
7. The manufacturer declines all responsibility for injury or
damage resulting from failure to observe these instructions.
Fig.1
~
1
0

TECHNICAL SPECIFICATIONS:

Optimal water pressure 3 bar hot – 3 bar cold
Permitted water pressure from 1 to 5 bar
Power supply 230 V a.c. - 50 Hz
Absorbed power rating 2500W
Electrical functions:
Finnish sauna
Chrome therapy
FM radio
-Frequency range 87-108 MHz
-Sensitivity 2.5µV-S/N 20dB
-Automatic AFC device.
-PU=2x5W
-D ≤ 10%
31
WASTE DISPOSAL:
For the disposal of the product or its parts, follow the local
regulations on matters of waste disposal. For Italy, Legislative
Decree n. 152 of April 3, 2006 will hold, and for the other EU
countries, Directive 2008/98/EC.
EC DECLARATION OF CONFORMITY:
The manufacturer Opus Engineering S.r.l. via Mantova,
1023, 46030 Borgo Virgilio (MN) Italy declares under its
responsibility that the Ares model cubicle fitted with steam
generator mod. S 400 conforms with the following European
directives EEC 73/23, EEC 89/336, EEC 2004/108 as amended
EEC 92/31, EEC 93/68
and with the following European standards:
(EN50366)
(EN55014-1)
(EN55014-2)
(EN60335-1)
(EN60335-2-15)
(EN61000-3-2)
(EN61000-3-3)
(EN61000-4-2)
(EN61000-4-3)
(EN61000-4-4)
(EN61000-4-5)
(EN61000-4-6)
(EN61000-4-11)
, (refer to figure
600 mm
2400 mm
2
3
(I)
Romanore di Borgo Virgilio, lì 31.10.2008
ENGLISH
Opus Engineering S.r.l.
Alberto Filipponi
Amministratore delegato
Tabla de contenido
loading

Tabla de contenido