5.1.1

Gravity fed system

A, G
System specific requirements
The correct installation and constant water level in the pond are important prerequisites for ensuring
optimum and fault-free operation of the gravity fed system.
Making a filter pit:
Excavate a pit of sufficient dimensions to accommodate the filter system.
Horizontally align the base slab.
Secure the walls of the pit from falling in (with masonry or concrete).
Ensure that the pit is protected from flooding. Provide a rain water drain.
Installing the filter system:
Determine the max. water level of the pond.
The base slab supporting the filter system must be 685 mm below the max. water level (max.
tolerance: -20 mm).
Keeping the water level constant:
A constant water level in the pond is necessary for operating the gravity fed system. Tolerances of
up to -20 mm from the max. water level are permitted.
If the max. water level in the pond is exceeded, water flows out of the Drum Filter Module via the
dirt channel until the max. water level is reached again.
If the water level goes below the max. water level by more than 20 mm, it is not possible to
achieve optimum or fault-free operation.
Install the OASE ProfiClear Guard refill system. The ProfiClear Guard refill system automatically
supplies water to the pond if the water level goes below the specified water level.
5.1.2

Pump fed system

B, C, H
System specific requirements
Horizontally align the base slab.
Install the Drum Filter Module 150 mm higher than the subsequent Moving Bed Module so that the
connections of the two modules (outlet and inlet) are at the same height.
Tip: Use three commercially available concrete slabs, each measuring 500 × 500 × 50 mm.
Position the outlet of the filter system such that the water level in the drum filter module is 230 ... 350
mm below the edge of the container.
Otherwise, optimum or fault-free operation will not possible.
Position the inlet in the pond (e.g. via a water course or waterfall) so that it is lower than the outlet of
the filter system.