3.3
Unit configuration
Gravity fed
GB
system
1
2
3
4
5
6
7
8
9
10
11
12
—
—
—
—
17
18
19
20
21
22
23
24
25
26
27
E
Pump fed
Description
system
1
Container cover
2
Signal box with level detection device (3) and temperature probe (4)
The signal box is connected to the control system (19, 21)
−
3
Level detection device
Signals the water level in the filter system
−
4
Temperature probe
monitors the water temperature
−
5
Filter drum with eight screen elements
screen elements for coarse dirt down to 60 µm in size (also optionally
−
available with 150 µm)
6
Rinsing device
sprays water at high pressure onto the screen elements (5) to rinse off
−
the coarse dirt
7
Dirt channel
collects the coarse dirt and rinsing water from the screen elements (5)
−
8
2 x DN 150 outlet
9
Rinsing pump for supplying the rinsing device (6)
10
Rollers for guiding the filter drum
11
DN 75 dirt outlet with slide valve
12
5 × spare expansion seals
13
50 mm (2 ") connection set
14
2 x adapter, 2 x 30° inlet bend with cap nut for connection of the UVC
water pre-treatment device Bitron to 38 mm (1½ ") connections (16)
15
2 x 50 mm (2 ") connection for connecting the filter pumps
16
2 × 38 mm (1½") connection, closed with sealing plugs
optional connection for a Bitron UVC water pre-treatment device
−
17
DN 110 dirt outlet for coarse dirt
18
Drum motor for filter drum
the motor is connected to the control system (19, 20)
−
19
2 × ground stakes for installing the control system
20
Control system
21
Connector for drum motor
22
Connector for signal box
23
Power cable
24
Connector for rinsing pump
25
Fuse holder
Fuse protection of the control system with 5 × 20 mm, T8 A 250 V
−
safety fuse
—
DN 110 inlet
−
—
3 × DN 110 inlets, with cover cap
For optional use
−
- GB -
43