FILTER ASSEMBLY/REPLACEMENT
1. Grasp the drum latches on both the right and left side of the power head. Slowly
pull the drum latches out and up from the drum. Lift the power head off the
drum. Place the lid assembly of the Vacuum upside down (Figure B).
2. Carefully slide the filter over the filter cage, sliding filter down until the filter
stops against the lid (Figure C).
NOTE: The filter will take the shape of the oval filter cage when in place.
3. Place filter nut onto threaded screw and tighten it down. Finger tighten only.
NOTE: Lever of filter nut should be away from filter as shown.
IMPORTANT: Do not overtighten as this may deform or damage the filter cage or
filter.
4. To assemble the power head to the drum, position power head over drum, with
drum latches lined up with recess in drum. (The power head will only fit on the
drum one way.)
5. Position bottom of the latch in drum recess. Push top of latch towards power
head to lock.
6. Your Vacuum is now ready to use. Read the instructions on the following pages
to operate your Vacuum safely.
Power
Head
Latch (one
on each
side)
PULL LATCH OUT
FROM THE TOP
AND UP FROM
THE BOTTOM
Figure B
ProTeam
Filter Nut
Filter
Threaded
Screw
Filter
Cage
Figure C
Power
Head
7