Requirements For Installation Position; Requirements Of The Mounting Structure; Electrical Safety Requirements - mabe MMI12CABWCAAXM8 Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

requirements For Installation Position

1.
are strongly aggressive gases.
2.
3.
Avoid places subject to noise and resonance.
4.
Avoid severe natural conditions (e.g. heavy lampblack, strong sandy
wind, direct sunshine or high temperature heat sources).
5.
Avoid places within the reach of children.
6.
Shorten the connection between the indoor and outdoor units.
7.
Select where it is easy to perform service and repair and where the
ventilation good.
8.
The outdoor unit shall not be installed in any way that could occupy
9.
The outdoor unit shall be installed as far as possible from the
doors and windows of the neighbors as well as the green plants.

requirements of the mounting structure

1.
The mounting rack must meet the relevant national or industrial
standards in terms of strength with welding and connection
areas rustproofed.
2.
The mounting rack and its load carry surface shall be able to
withstand 4 times or above the weight of the unit, or 200kg,
whichever is heavier.
3.
The mounting rack of the outdoor unit shall be fastened with
expansion bolt.
4.
Ensure the secure installation regardless of what type of wall
on which it is installed, to prevent potential dropping that could
hurt people.

electrical safety requirements

1.
Be sure to use the rated voltage and air conditioners dedicated circuit
for the power supply, and the power cord diameter must meet the
national requirements.
2.
When the maximum current of air conditioner is ≥16A, it must use
the air switch or leakage protection switch equipped with
protection devices.
3.
The normal operating range is 90%-110% of the local rated voltage.
4.
The minimum clearance between the air conditioner and the
combustibles is 1.5 m.
5.
The power cable enables communication between the indoor and
preparing it for connection.
6.
Cable Types:
Outdoor Power Cord: H07RN-F or H05RN-F;
Power Cable: H07RN-F or H05RN-F;
7.
Minimum Cross-Sectional Area of Power and Power Cables
57